D G F r
6000-2960-0000-1XX 29600-2018 V102 02 ⁄ 2018
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Anlegetemperaturfühler ⁄ Rohranlegefühler,
incl. Spannband, mit passivem Ausgang
G
Operating Instructions, Mounting & Installation
Surface contact temperature sensors ⁄ tube contact sensors,
including strap, with passive output
F
Notice d'instruction
Sonde de température à applique ⁄ sonde d'applique pour conduites,
y compris collier de serrage, avec sortie passive
r
Руководство по монтажу и обслуживанию
Датчик температуры накладной ⁄ накладной для труб,
вкл. хомут, с пассивным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
ALTF 1
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Thermasgard ALTF 1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for S+S Regeltechnik Thermasgard ALTF 1

  • Page 1 Руководство по монтажу и обслуживанию Датчик температуры накладной ⁄ накладной для труб, вкл. хомут, с пассивным выходом S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben. PIRNAER STRASSE 20 Congratulations! 90411 NÜRNBERG ⁄...
  • Page 2 D G F r ALTF 1 THERMASGARD ®  Maßzeichnung ALTF 1 Dimensional drawing Plan coté Габаритный чертеж...
  • Page 3: Technische Daten

    ® THERMASGARD ALTF1 Rev. 2018 - V12 DE THERMASGARD ® ALTF 1 Anlegefühler sind elektrische Berührungs thermometer, die der 1x Zweileiterschaltung Messung von Ober flächentemperaturen fester Körper dienen und mindestens eine sogenannte Standard Anlegefläche oder Kontakt fläche haben, die mit der zu messenden Oberfläche in Berührung gebracht wird.
  • Page 4 Allgemeine Informationen Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatursensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751) c) Ni 1000 - Messwiderstand (nach DIN EN 43 760, TCR=6180 ppm ⁄...
  • Page 5 Montage und Installation Die Geräte sind im spannungslosen Zustand anzuschließen. Der Hinweise zum mechanischen Ein- und Anbau: Anschluss der Geräte darf nur an Sicherheitskleinspannung er- Der Einbau hat unter Berücksichtigung der einschlägigen, für den folgen. Folgeschäden, welche durch Fehler an diesem Gerät ent- Messort gültigen Vorschriften und Standards (wie z.
  • Page 6: Technical Data

    ® THERMASGARD ALTF 1 Rev. 2018 - V12 GB THERMASGARD ® ALTF 1 surface contact sensors are electric contact thermometers and are 1x two-wire connection used for measuring surface temperatures of solids, having at least one so-called contact area Standard that is brought into contact with the surface to be measured.
  • Page 7 General notes Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Page 8 Mounting and Installation Devices are to be connected under dead-voltage condition. Devices Notes regarding mechanical mounting and attachment: must only be connected to safety extra-low voltage. Consequential Mounting shall take place while observing all relevant regulations damages caused by a fault in this device are excluded from war- and standards applicable for the place of measurement (e.g.
  • Page 9: Caractéristiques Techniques

    ® THERMASGARD ALTF 1 Rev. 2018 - V12 FR Les sondes d’applique THERMASGARD ® ALTF 1 sont des thermomètres électriques de contact 1 x 2 fils qui servent à la mesure de températures sur les surfaces de corps solides et qui disposent d’au Standard moins une surface d’applique ou d’au moins une surface de contact qui sera mise en contact avec la surface à...
  • Page 10 Généralités Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé par le type de capteur qui se trouve à l’intérieur. On distingue les capteurs de température actifs et passifs suivants: a) Pt 100 –...
  • Page 11 Montage et installation Les raccordements électriques doivent être exécutés HORS Consignes pour l’installation mécanique : TENSION. Veillez à ne brancher l’appareil que sur un réseau de Effectuer le montage en tenant compte des dispositions et règles très basse tension de sécurité. Nous déclinons toute responsabi- standards à...
  • Page 12: Технические Данные

    ® THERMASGARD ALTF 1 Rev. 2018 - V12 RU Накладные датчики THERMASGARD ® ALTF 1 являются электрическими контактными термометрами, 1x Двухпроводное подключение служащими для измерения температуры поверхности твердых тел и имеющими одну или несколько стандартное т.  н. контактных или присоединительных поверхностей, которые приводятся в соприкосновение с...
  • Page 13 Указания к продуктам Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находящего- ся внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассивные ⁄ активные чувствительные элементы: а) измерительный...
  • Page 14 Монтаж и подключение Приборы следует устанавливать в обесточенном состоянии. Под- Указания к механическому монтажу: ключение должно осуществляться исключительно к безопасно ма- Монтаж должен осуществляться с учетом соответствующих, дей- лому напряжению. Повреждения приборов вследствие несоблюде- ствительных для места измерения предписаний и стандартов ния...
  • Page 15 Reprints, in part or in total, are only permitted with the approval of S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры PT 100 PT 1000 Ni 1000 Ni 1000 LM235Z TK 5000 (T1) 81-210 (KP10) °...