Environmental Protection; What Your 3 Year Warranty Means; Service Support; Troubleshooting - ALDI Workzone Titanium+ 62007 User Manual

2200w inverter generator with pure sine wave
Table of Contents

Advertisement

Environmental Protection

Environmental Protection
Recycle unwanted materials instead of disposing of them as waste.
All tools, hoses and packaging should be sorted, taken to the local
recycling centre and disposed of in an environmentally safe way.
Dispose of used motor oil in a manner that is compatible with the
environment.
We suggest you take it in a sealed container to your local service station for
reclamation. Do not throw it in the trash or pour it into the earth.

What your 3 year warranty means

Great care has gone into the manufacture of this product and it should
therefore provide you with years of good service when used properly.
In the event of product failure within its intended use over the course of
the first 3 years after the date of purchase, we will remedy the problem as
quickly as possible once it has been brought to our attention. In the unlikely
event of such an occurrence, or if you require any information about the
product please contact us via our after sales support services, details of
which can be found in this manual and on the product itself. After Sales
Support TEL: 1800 909 909

Service Support

If you are having difficulty in using your product, you can find instructional
Know How videos on our website, https://help.tools/ by clicking on the
"How to videos" link.
If you have any issues with the operation of your product, please take it with
a copy of your receipt to one of our National Service Agents for repair or call
us 1800 909 909 for advice.
A listing of our Service Agents is included with your product, however,
you can also find our most updated listing on our website
https://help.tools/ by clicking on the Service Agent link.
34
e-mail: help@powertoolsupport.com
MODEL: №. EP2800i • 09/2018 • 62007
Digital Inverter Generator with Pure Sine Wave
AFTER SALES SUPPORT
1800 909 909
Digital Inverter Generator with Pure Sine Wave
Trouble
Engine will not start
AFTER SALES SUPPORT
(toll free)
(toll free)

Troubleshooting

Possible cause
1. Low on fuel or oil content
2. Engine On/Off switch (2) in "Off"
position
3. Faulty spark plug (20)
4. Choke lever (16) in wrong position
5. Fuel shut-off valve in closed position
6. Unit loaded during start-up
7. Spark plug (20) wire loose
8. Old fuel in carburettor
9. If all of the above checked ok
1800 909 909
Troubleshooting
Suggested remedy
1a Fully fill tank. Ensure fuel is fresh
1b Ensure oil is at the the correct level.
Refer page 21-22 of this manual.
1c Ensure the generator is horizontal and
not on an angle
1d Turn Off the fuel tap / lever (23).
Loosen the carburettor drain screw.
Allow the fuel in the carburettor bowl
to totally drain. When the fuel has
stopped draining, open the fuel tap /
lever (23) on the tank and fuel starts
running out of the carburettor drain. If
so, tighten the screw on the drain and
allow the carburettor to fill with petrol.
1e If the fuel from the tank does not pass
through the carburettor drain above,
you need to drain the fuel tank (27),
remove the fuel tap / lever (23) and
inspect the fuel extension filter (22).
2. Press the engine On/Off switch (2) to
the "ON" position as indicated by an "I".
3. Replace or clean spark plug (20)
Refer page 30.
4. Adjust choke lever (16) accordingly
Refer to page 23.
5. Open fuel shut-off valve
6. Remove load from unit
7. Attach wire to spark plug (20)
8. Fuel will deteriorate in the carburettor
fuel bowl very quickly. Open the drain
screw in the bowl of the carburettor
until fresh fuel runs through.
9. Take unit to service centre