ALDI Workzone Titanium+ 62007 User Manual

ALDI Workzone Titanium+ 62007 User Manual

2200w inverter generator with pure sine wave

Advertisement

User Manual
62007
2200W INVERTER GENERATOR
WITH PURE SINE WAVE
Product
Info
https://help.tools/
Read all safety warnings and all instructions
thoroughly before operating this product.
Ensure you keep your manual in a
safe place for future reference.
IM Ed7 09/2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Workzone Titanium+ 62007 and is the answer not in the manual?

Questions and answers

Marcus sansom
March 7, 2025

Engine will start but can’t get any charge from it what the problem please

1 comments:
Mr. Anderson
March 7, 2025

If the ALDI Workzone Titanium+ 62007 engine starts but does not provide any charge, the problem could be an overload condition. This is indicated by the red load status indicator light, which means a fault has been detected, and the power supply to the control panel has been interrupted. In this condition, no 240V AC is available to the panel, and the green indicator will not operate.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for ALDI Workzone Titanium+ 62007

  • Page 1 User Manual 62007 2200W INVERTER GENERATOR WITH PURE SINE WAVE Product Info https://help.tools/ Read all safety warnings and all instructions thoroughly before operating this product. Ensure you keep your manual in a safe place for future reference. IM Ed7 09/2018...
  • Page 2: Table Of Contents

    Just scan the QR code with your smartphone and Normal Procedure for Stopping the Engine Product find out more about the Aldi product you have Overload procedure for restarting and resetting the engine Info Emergency Stop, and / or failure of On/Off switches purchased*.
  • Page 3: Pack Contents / Parts

    Digital Inverter Generator with Pure Sine Wave Pack contents / parts Description of symbols Congratulations on the purchase of your Workzone® Titanium Inverter The rating plate on your Inverter Generator may show symbols. These represent Generator with Pure Sine Wave. When you open your packaging, first remove all items important information about the product or instructions on its use.
  • Page 4: General Safety Warnings

    c. Prevent unintentional starting. Ensure the switch is in the “off” position when starting, picking up or carrying the tool. Carrying power tools with your finger on General safety warnings the switch or energising power tools that have the switch on invites accidents. d.
  • Page 5: Additional Safety Rules For Petrol Products

    • Any extension cable should be of heavy duty, 3 core and rated to 15A, and suitable for outdoor applications. Additional Safety Rules for Petrol Products • Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank.
  • Page 6: Safety Risk

    Safety Risk Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Safety Risk Safety Risk Risk of fire Hazard What could happen How to prevent it Fuel and fuel vapours can become ignited Turn engine off and allow it to cool before Attempting to fill the fuel by coming in contact with hot components adding fuel to the tank.
  • Page 7: Risk Of Unsafe Operation

    Safety Risk Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Assembly Assembly Risk of unsafe operation Hazard What could happen How to prevent it This generator requires assembly of the anti-vibration feet onto the generator. All sources of energy include •...
  • Page 8: Parts List

    Parts List Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Parts List Parts List 240Va.c Outlet Power On/Off switch Engine On/Off switch Side carry handles (2) Low oil indicator light Load Status indicator light Power Supply indicator light Muffler Exhaust / spark arrestor...
  • Page 9: Intended Use Of The Generator

    Intended Use Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Intended Use Other combinations: Intended use of the Generator Caravan fridge (200w) + toaster (1600w) + drill (1100w) = 2900w Inverter technology Caravan water heater (1500w) + globe (60w) + TV (200w) = 1760w This generator has been developed with inverter technology providing...
  • Page 10: Preparation Information

    Preparation information Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Preparation Information c. Flashing 3 times indicates overload protection caused by an excessive Preparation Information electrical overload. d. Flashing 4 times indicates there is an electrical problem most likely caused Indicators by a short circuit.
  • Page 11: Filling & Checking The Engine Oil

    Preparation Information Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Preparation Information WARNING. 1. Before checking or refilling oil, be sure the generator is put on a stable and level surface, • Do not refill fuel tank (26) while engine is running or is hot. ensuring the engine has been switched OFF.
  • Page 12: Engine Oil Replacement

    Operation Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Operation Engine oil replacement Starting your Generator 1. Place the generator on a flat and level surface and NOTE: As the oil tank is not shipped with oil before starting the engine, warm up the engine for several minutes.
  • Page 13 Operation Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Operation 7. You can now one at a time, 4.   Press the engine On/Off switch (2) to the “ON” green position as indicated by an “I” down (Fig. O). This generator will not start without this switch in physically plug in your appliances the ON position.
  • Page 14: Overload Condition

    Operation Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Operation Normal procedure for Stopping the Engine WARNING: All appliances are rated differently. This generator will work only with Australian approved rated appliances with an input voltage of (Full shut down and Store) 220-240Va.c (Fig T).
  • Page 15: Emergency Stop, And / Or Failure Of On/Off Switches

    Operation Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Storage Emergency Stop, and / or failure of On/off Switches Storage (NOT RECOMMENDED EXCEPT IN EMERGENCY) In the case of an emergency that requires the generator to be shut down as •...
  • Page 16: Maintenance

    Maintenance Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Maintenance Spark Plug Maintenance To ensure the engine is operating correctly, the spark plug must be properly gapped and free of carbon deposits. Always check the spark plug cable is Periodic Maintenance firmly fitted to the top of the spark plug.
  • Page 17: Air Filter

    Maintenance Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Maintenance Air Filter Fuel Tank Inlet Filter It is very important to maintain an air filter (18) in proper condition. Damage to WARNING: Ensure the engine is switched off while undertaking the generator may arise if the filter has: this task.
  • Page 18: Cleaning

    Maintenance Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Cleaning 1. Completely empty the tank of fuel. Ensure the fuel tap/lever (23) is in the Cleaning OFF position. 2. Compress the two wire arms of the hose clamp on the outlet hose at the 1.
  • Page 19: Environmental Protection

    Environmental Protection Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Troubleshooting Environmental Protection Troubleshooting Recycle unwanted materials instead of disposing of them as waste. Trouble Possible cause Suggested remedy All tools, hoses and packaging should be sorted, taken to the local 1.
  • Page 20: Accessories And After Sales

    Troubleshooting Digital Inverter Generator with Pure Sine Wave Digital Inverter Generator with Pure Sine Wave Specifications Specifications Trouble Possible cause Suggested remedy 1. Faulty receptacle 1. Have service centre replace receptacle No electrical output 2. Overload has been triggered 2. Remove all appliances. Stop the (red Overload light on).
  • Page 21 If you are not entirely satis ed with this product, please return it to your nearest ALDI store, within 60 days from the date of purchase, for a full refund or replacement, or take advantage of our after sales support by calling the supplier’s Customer Service Hotline.

Table of Contents