Omron G3ZA User Manual page 29

Multi-channel power controller
Hide thumbs Also See for G3ZA:
Table of Contents

Advertisement

CompoWay/F Frame Structure
End Codes (CompoWay/F Communications)
Data Type Notation
16
End code
Name
"0F"
FINS command
error
"10"
Parity error
"11"
Framing error
"12"
Overrun error
"13"
BCC error
"14"
Format error
"16"
Subaddress error
"18"
Frame length error
"00"
Normal end
In this manual, hexadecimal and ASCII characters are expressed as shown in
the following table.
Hexadecimal
An H is added to the end of the hexadecimal number.
Example: 02H
ASCII characters
ASCII characters are given in quotation marks.
Example: "00"
Description
Could not execute the specified FINS command.
Sum of bits that are "1" in received data does not
agree with the set communications parity value.
Stop bit is "0".
The next data was received when the received
data buffer was full.
Calculated BCC differs from received BCC.
Characters other than "0" to "9" or "A" to "F" in
FINS-mini command text. (Refer to 3-9 Echo-
back Test on page 22 for echo-back tests.)
One or more of the subaddresses is missing.
The received frame exceeds the required num-
ber of bytes.
Command was executed normally without error.
Section 3-2

Advertisement

Table of Contents
loading

Table of Contents