Functions Of The Switches And Leds - elero PatioControl Operating Instructions Manual

Pergola control unit
Hide thumbs Also See for PatioControl:
Table of Contents

Advertisement

4.1

Functions of the switches and LEDs

DIP switch S1
1
Actuator radio receiver power supply
2
Light module radio receiver power supply
DIP switch S2
1
Actuator locked at temperatures below
-5º
2
Snow function
3
only one actuator (M1)
4
rain alarm direction of travel
Key
S3
press and hold >3 s: delete limit positions
S4
close pergola
S5
open pergola
*) factory setting
PatioControl
ON
OFF
LED
On*
Off
1
On*
Off
1
ON
OFF
2
On
Off *
2
On
Off *
2
On*
Off
Open
Close*
[Teach-in hand-held transmitter]
Colour
Type of
fl ashing
Green
permanent
Green
steady
Red
Twice in 6 s
Red
Three times in
6 s
Red
Four times in 6 s
NOTE
Temperature sensor
An optional temperature sensor is required in order to
be able to use the snow, protection from freezing and
actuator lock at temperatures < -5 ºC.
Meaning
Ready to teach in
paths
Path limits are
teached-in
Rain alarm
Snow alarm
Wind alarm
19