Serial Interface
Serial Settings
RS-485 ASCII
19200 baud, 8, N, 1
RS-422 ASCII
19200 baud, 8, N, 1
RS-422 NMEA
4800 baud, 8, N, 1
6.4 Communication Setting Commands
In this section, the commands the user types are presented in normal text while the
responses of the transmitter are presented in italic.
6.4.1 Checking Current Communication Settings (aXU)
Use this command to request the current communication settings.
Command format in ASCII and NMEA 0183:
aXU<cr><lf>
Command format in SDI-12:
aXXU!
a
XU
XXU
<cr><lf>
!
Example response in ASCII and NMEA 0183:
aXU,A=a,M=[M],T=[T],C=[C],I=[I],B=[B],D=[D],P=[P],S=[S],
L=[L],N=[N],V=[V]<cr><lf>
Example response in SDI-12:
72
sales@streamlinemeasurement.co.uk
Device address, which can consist of the following characters: 0 (default) ... 9, A ... Z,
a ... z.
Device settings command in ASCII and NMEA 0183
Device settings command in SDI-12
Command terminator in ASCII and NMEA 0183
Command terminator in SDI-12
01457-864334
M211840EN-D
www.streamlinemeasurement.co.uk