Equipment Setup Options - Honeywell Lyric T5 Quick Install Manual

Wi-fi thermostat
Hide thumbs Also See for Lyric T5:
Table of Contents

Advertisement

Available languages

Available languages

Equipment Setup Options

Option #
Option Name
120
Schedule Type
200
System Type
205
Equipment Type
218
Reversing Valve
220
Cool Stages /
Compressor Stages
#200=Conventional/
200=Heat Pump
221
Heat Stages,
Aux/E Stages
#200=Conventional/
200=Heat Pump
33-00151EF_A.indd 18
Option Value (factory default in bold)
No Schedule
MO-SU = Every day the same
MO-FR SA SU = 5-1-1 schedule
MO-FR SA-SU = 5-2 schedule
Each Day = Every day different
Note: You can change default MO-FR, SA-SU schedule here. To edit periods during days,
temperature setpoints, or to turn Schedule On/Off, touch MENU and go to SCHEDULE.
Conventional Forced Air, Heat Pump, Boiler, Cool Only
Note: This option selects the basic system type your thermostat will control.
Conventional Forced Air Heat:
Standard Gas, High Efficiency Gas, Oil, Electric, Hot Water Fan Coil
Heat Pump:
Air to Air, Geothermal
Radiant Heat:
Hot Water, Fan Coil, Steam
Note: This option selects the equipment type your thermostat will control. Note: This
feature is NOT displayed if feature 200 is set to Cool Only.
O/B on Cool, 0/B on Heat
Note: This option is only displayed if the Heat Pump configured. Select whether reversing
valve O/B should energize in cool or in heat.
0, 1, 2
Note: Select how many Cool or Compressor stages of your equipment the thermostat will
control. Maximum of 2 Cool/Compressor Stages.
Heat Stages: 0, 1, 2
Aux/E stages: 0, 1
Note: Select how many Heat or Aux/E stages of your equipment the thermostat will
control. Maximum of 2 Heat Stages for conventional systems. Maximum of 1 Aux/E stage
for systems with more than 1 heating equipment type.
18
6/24/2016 4:20:51 PM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents