System Setup Options - Honeywell Z-Wave Series Quick Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

Quick Installation Guide

System Setup options

To access all system options in the table below, press and hold MENU for 5 seconds.
or
Touch
to scroll through the list.
Number
Description
120
Scheduling Options
Temperature Indication
125
Scale
130
Outdoor Temp
200
Heating System Type
Heating Equipment
205
Type
218
Reversing Valve O/B
Cool Stages /
220
Compressor Stages
200=Conv / 200=HP
Heat Stages / Backup
221
Heat Stages Heat
Stages
230
Fan Control
253
Aux/E Control
255
Aux Heat Type
0 = Non-Programmable
1 = 1-Week Programmable
2 = 5-2 Programmable
3 = 5-1-1 Programmable
4 = 7-Day Programmable
Note: You can change default MO-FR, SA-SU schedule here. To edit periods during days,
temperature setpoints, or to turn Schedule On/Off, touch MENU and go to SCHEDULE.
0 = Fahrenheit
1 = Celsius
No, Wired
Note: An outdoor temperature is required to set the following ISUs: ISU 355 Balance point
(Compressor Lockout), ISU 356 Aux Heat Lockout. Use a wired outdoor sensor connected
to the "S" terminals on the UWP and set this ISU to Wired. (See "Wiring—heat pump" on
page 21.)
1 = Conventional Forced Air Heat
2 = Heat Pump
3 = Radiant Heat (Boiler)
5 = None (Cool Only)
Note: This option selects the basic system type your thermostat will control.
Conventional Forced Air Heat:
1 = Standard Efficiency Gas Forced Air
2 = High Efficiency Gas Forced Air
3 = Oil Forced Air
4 = Electric Forced Air
5 = Hot Water Fan Coil
Heat Pump:
7 = Air to Air Heat Pump
8 = Geothermal
Radiant Heat:
9 = Hot Water Radiant Heat
12 = Steam
Note: This option selects the equipment type your thermostat will control. Note: This feature is
NOT displayed if feature 200 is set to Cool Only.
0 = O (O/B in Cool)
1 = B (O/B in Heat)
Note: This option is only displayed if the Heat Pump configured. Select whether reversing valve
O/B should energize in cool or in heat.
0, 1, 2
Note: Select how many Cool or Compressor stages of your equipment the thermostat will
control. Maximum of 2 Cool/Compressor Stages. Set value to 0 if you do not have Cool Stage/
Compressor Stage.
Heat Stages: 1, 2
Backup Heat Stages: 0, 1
Note: Select how many Heat or Aux/E stages of your equipment the thermostat will control.
Maximum of 2 Heat Stages for conventional systems. Maximum of 1 Aux/E stage for systems
with more than 1 heating equipment type. Set value to 0 if you do not have Heat Stage/Backup
Heat Stage.
1 = Equipment
2 = Thermostat
Note: This ISU is only displayed if ISU 205 is set to Electric Forced Air or Fan Coil.
Both Aux/E, Either Aux/E
Note: Set "EITHER AUX/E" if you want to setup and control of Auxiliary and Emergency heating
separately . This ISU is only displayed if ISU 200 is set to Heat Pump AND if ISU 221 Aux/E
stages = 1.
Electric, Gas/Oil (or Fossil Forced Air)
Note: This ISU is displayed only if ISU 200 is set to heat pump AND if ISU 221 Aux/E heat
stages = 1.
10
Options (factory default in bold)