Proline Prowirl R 200 HART
Parameter
Switch output function
Assign diagnostic behavior
Assign limit
Assign flow direction check
Assign status
Switch-on value
Switch-off value
Endress+Hauser
Parameter overview with brief description
Prerequisite
The Switch option is selected
in the Operating mode
parameter.
• In the Operating mode
parameter, the Switch
option is selected.
• In the Switch output
function parameter, the
Diagnostic behavior option
is selected.
• The Switch option is
selected in the Operating
mode parameter parameter.
• The Limit option is selected
in the Switch output
function parameter
parameter.
• The Switch option is
selected in the Operating
mode parameter.
• The Flow direction check
option is selected in the
Switch output function
parameter.
• The Switch option is
selected in the Operating
mode parameter.
• The Status option is
selected in the Switch
output function parameter.
• In the Operating mode
parameter, the Switch
option is selected.
• In the Switch output
function parameter, the
Limit option is selected.
• In the Operating mode
parameter, the Switch
option is selected.
• In the Switch output
function parameter, the
Limit option is selected.
Description
Select function for switch
output.
Select diagnostic behavior for
switch output.
Select process variable for limit
function.
Select process variable for flow
direction monitoring.
Select device status for switch
output.
Enter measured value for the
switch-on point.
Enter measured value for the
switch-off point.
Commissioning
Selection / User
Factory setting
entry
• Off
Off
• On
• Diagnostic
behavior
• Limit
• Status
• Alarm
Alarm
• Alarm or warning
• Warning
• Volume flow
Volume flow
• Corrected volume
flow
• Mass flow
• Flow velocity
• Temperature
• Pressure
• Calculated
saturated steam
*
pressure
*
• Total mass flow
*
• Energy flow
• Heat flow
*
difference
*
• Reynolds number
• Totalizer 1
• Totalizer 2
• Totalizer 3
• Off
Volume flow
• Volume flow
• Mass flow
• Corrected volume
flow
Low flow cut off
Low flow cut off
Signed floating-point
Country-specific:
number
• 0 m³/h
• 0 ft³/h
Signed floating-point
Country-specific:
number
• 0 m³/h
• 0 ft³/h
91