Unit Doesn't Power Up:
1. Make sure you have 120VAC going to the outlet.
2. Check the fuse on the power supply by removing the (4) four screws securing the power
supply cover, tilting the top of cover forward.
3. Fuse holder cap will be on the upper right hand side of the power supply.
4. Using a flat head screwdriver, rotate the cap counterclockwise quarter turn to remove the
fuse.
5. Test the fuse with an ohmmeter to check if it is blown.
6. If the fuse is blown, replace it with a 250-volt, 1-amp fuse and reinstall fuse cap and power
supply cover.
Lazy Segments:
1. If a lazy segment is detected and you are using the optional 12-volt battery be sure the battery is
fully charged.
2. If the battery is fully charged and the lazy segment appears to be in only one or two digits remove
the digit window as described in the digit removal procedure.
3. Carefully move the suspect segment back and forth with your finger to free any debris.
4. Using compressed air only, blow excess debris out of segment works.
5. If problem persists, contact Eversan, Inc.
Do not spray digits with any lubricants. Doing so will void the warranty.