Please fi ll out the form(s) below for each instrument that has been purchased. Use this information when contacting Michell Instruments for service purposes. Transmitter Code Serial Number Invoice Date Location of Instrument Tag No Transmitter Code Serial Number Invoice Date...
The instrument should be returned to the manufacturer, Michell Instruments Ltd., or one of their accredited service agents for re-calibration. Safety Conformity This product meets the essential protection requirements of the relevant EU and US standards and directives.
Easidew Transmitter User’s Manual Abbreviations The following abbreviations are used in this manual: barg pressure unit (=100 kP or 0.987 atm) gauge ºC degrees Celsius ºF degrees Fahrenheit direct current ft-lbs foot-pound force grams inch(es) μm micrometer m/sec meters per second...
INTRODUCTION INTRODUCTION The Michell Instruments Easidew is a 4-20mA loop-powered dew-point transmitter, designed to make dew point measurements in a fl owing sample. The Easidew transmitter is available with 3 different process connections: • 5/8" - 18 UNF : Easidew 2-wire, Easidew M12 •...
Easidew Transmitter User’s Manual INSTALLATION INSTALLATION Unpacking the Instrument On delivery, please check that all the following standard components are in the packing tube: • Easidew Transmitter • Certifi cate of Calibration • Connector (for sensor/cable) The Transmitter will also be supplied with a process seal, which will be fi tted to the unit.
Michell Instruments representative (see www.michell.com for details). DIN 43650 Version Cable connection to the Easidew transmitter is made via the removable connector. Removing the central screw enables the connector terminal block to be removed from the outer housing by using a small screwdriver to prise it clear.
Page 10
(see Figure 3) before the power is applied. Without this connection, the transmitter may be damaged if allowed to operate for prolonged periods. M12 5-Pin Version Cables with moulded M12 connectors are available from Michell Instruments in the following lengths: • 0.8m •...
Easidew Transmitter User’s Manual INSTALLATION this precaution can result in ground loops and equipment malfunction. Cable Connection DIN 43650 Version To ensure the specifi ed ingress protection is achieved, when installing the connector, the securing screw (with the O-ring and washer) must be tightened to a minimum torque of 3.4 Nm (2.5 ft-lbs).
Figure 8 2.4.2 Digital Communication (M12 Version only) Modbus RTU over RS485 communication is available on the Easidew M12, and can be used simultaneously with the 2-wire current output. Section 2.2 describes the electrical connections to the transmitter. The Modbus register map can be found at the end of this manual.
Page 13
Easidew Transmitter User’s Manual INSTALLATION Examples of such conditional limitations are: • Excessive fl ow rate • Presence of particulates matter • Presence of entrained liquids • Excessive sample temperature The basic considerations for each measurement type are as follows: In-Situ Dew-Point Sensor Position –...
Page 14
fi ltration. Sample Temperature – Although the Easidew can be operated at sample temperatures up to 70°C, it is advisable to keep the sample temperature as close to ambient, and as stable as possible to keep adsorption & desorption characteristics as consistent as possible (see section X.X Sampling Hints for...
Easidew Transmitter User’s Manual OPERATION Figure 11 Transmitter Mounting - Sensor Block 2.5.2 Sampling Hints Measurement of moisture content is a complex subject, but does not need to be diffi cult. This section aims to explain the common mistakes made in measurement situations, the causes of the problem, and how to avoid them.
Page 16
Easidew Transmitter User’s Manual OPERATION porous medium causing water to migrate into the pressurised air line. This effect is called transpiration. Adsorption and Desorption Adsorption is the adhesion of atoms, ions, or molecules from a gas, liquid, or dissolved solid to the surface of a material, creating a fi lm. The rate of adsorption is increased at higher pressures and lower temperatures.
Easidew Transmitter User’s Manual OPERATION The membrane filter is a more expensive but highly effective alternative to a coalescing filter. It provides protection from liquid droplets, and can even stop flow to the analyser completely when a large slug of liquid is encountered.
Easidew Transmitter User’s Manual MAINTENANCE 48mm Transmitter Mounting - Pipe or Duct Figure 14 2.5.3.1 5/8” 18 UNF Version Remove the protective cover and desiccant capsule from the transmitter and retain for future use Prevent any contamination of the sensor before installation by handling the transmitter by the main body only, avoiding contact with the sensor guard.
Easidew Transmitter User’s Manual APPENDIX A 2.5.3.2 3/4” - 16 UNF Version Remove the protective cover and desiccant capsule from the transmitter and retain for future use. Prevent any contamination of the sensor before installation by handling the transmitter by the main body only, avoiding contact with the sensor guard.
Page 20
The sensor guard should be replaced if the surface shows any damage or signs of discolouration. When replacing a guard, make sure to wear clkean disposable gloves, and handle by the threaded base section only. Replacement HDPE or stainless steel guards can be ordered from your Michell Instruments representative. HANDLE,...
Easidew Transmitter User’s Manual MAINTENANCE can be obtained by your Michell Instruments representative. O-ring Seal If the supplied O-ring seal is damaged or lost a pack of 5 replacement bonded seals can be obtained by contacting your Michell Instruments representative. Michell Instruments...
Easidew Transmitter User’s Manual APPENDIX B Appendix B Quality, Recycling & Warranty Information Michell Instruments...
Page 26
Easidew Transmitter User’s Manual APPENDIX B Appendix B Quality, Recycling & Warranty Information Michell Instruments is dedicated to complying to all relevant legislation and directives. Full information can be found on our website at: www.michell.com/compliance This page contains information on the following directives: •...
Easidew Transmitter User’s Manual APPENDIX C Appendix C Return Document & Decontamination Declaration Michell Instruments...
Page 28
Has the equipment been cleaned and decontaminated? NOT NECESSARY Michell Instruments will not accept instruments that have been exposed to toxins, radio-activity or bio-hazardous Work will not be carried out on any unit that does not have a completed decontamination declaration.
Page 29
Easidew Transmitter User’s Manual APPENDIX D Appendix D Modbus Register Map Michell Instruments...
Page 30
APPENDIX D Appendix D Modbus Register Map All the data values relating to the Easidew are stored in 16-bit wide holding registers. Registers can contain either measured or calculated values (dew-point, temperature, etc.), or confi guration data (output settings). Modbus RTU Implementation...
Page 31
Easidew Transmitter User’s Manual APPENDIX D Register Address Access Data Description Comment Type 0000 uint16 Instrument Modbus Address 1-255 0003 special Status/Fault Indication bit0, Sensor short circuit bit1, Sensor open circuit bit2, Thermistor short circuit bit3, Thermistor open circuit bit4, Sensor over range...
Page 32
Easidew Transmitter User’s Manual APPENDIX D 004E special Natural Gas Configuration & Natural gas configuration Precision Select bit1, 0=IGT, 1=ISO bit2, lb/MMscf bit3, ppmV NG bit4, mg/m Precision Select bit15, 0=1 Decimal Place, 1=4 Decimal Places Register confi guration in 1 decimal place precision mode...