1
MOUNTING & WIRING
1
Remove the bracket
from the sensor.
Drill 2 holes accordingly.
Mount the bracket firmly.
2
DETECTION FIELD ADJUSTMENTS
1
Adjust the angle of the sensor to position the detection field.
FALCON
Mounting height: 16 ft
All detection field dimensions were measured in optimal conditions and with field size value 9.
3
DETECTION FILTER
Choose the right detection filter for your application with the remote control or the push buttons:
Detection of all targets
(pedestrians and parallel traffic are detected)
1-6
1 = no specific filter
2 = filter against disturbances
(recommended in case of vibrations, rain etc.)
Page 2 of 4
2
Position the sensor on the
bracket and fasten the screws
firmly.
CEILING
WALL
FALCON XL
Mounting height: 8 ft
(REJECTION MODE)
Detection only of vehicles moving towards the sensor*
(pedestrians and parallel traffic are not detected + disturbances are filtered)
Value recommendations according to angle and height:
15°
30°
45°
+45°
* The vehicle detection filter increases the response time of the sensor.
3
RED
BLACK
WHITE
GREEN
YELLOW
Connect the wires to the door
controller. Choose between NO
and NC contact.
2
0-9
Adjust the field size with the
remote control or the push
buttons.
FALCON WIDE
Mounting height: 11.5 ft
23 ft - 11.5 ft
8 ft
Always check if the chosen
value is optimal for the
3
3
application.
4
4
The object size and nature
5
4
can influence the detection.
6
5
XL
75.5835.04 FALCON FAMILY 20160301
12-24 V
AC-DC
COM
NO
NC

Advertisement

loading

This manual is also suitable for:

Falcon xlFalcon wide