Specification - Mitsubishi Electric MUY-TP-VF Series Service Manual

Split type air conditioner
Table of Contents

Advertisement

3

SPECIFICATION

Indoor model
Power supply
Breaker Capacity
Power input 1 (Total)
Running current 1
(Total)
Power factor 1 (Total)
Starting current 1 (Total)
Model
Current
1
Dimensions W × H × D
Weight
Air direction
Fan speed regulator
NOTE : Test conditions are based on ISO 5151.
Cooling : Indoor
Outdoor Dry-bulb temperature 35°C
1 Measured under rated operating frequency.
Specifications and rated conditions of main electric parts
Fuse
Horizontal vane motor
Varistor
Terminal block
OBH816
A
Cooling
W
Cooling
A
Cooling
%
A
Cooling
A
mm
kg
Super High
High
m
3
/h
Med.
Low
Super High
High
dB(A)
Med.
Low
Super High
High
rpm
Med.
Low
Dry-bulb temperature 27°C
(F11)
(MV)
(NR11)
(TB)
MSY-TP35VF
Single phase 230 V, 50 Hz
10
760
3.6
91
3.6
RC0J30-MD
0.32
923 × 305 × 250
12.5
5
984
822
696
606
45
40
36
31
1,070
930
820
740
4
Wet-bulb temperature
19°C
T3.15AL250V
12 V DC
470 V
5P
5
MSY-TP50VF
1,450
6.4
98
6.4
990
1,080