ELEC
IGNITION SYSTEM
3. Measure:
Pulser coil output peak voltage
Above specification
unit.
Below specification
coil.
Pulser coil output peak voltage
White/red (W/R) – Black (B)
Circuit
r/min
Cranking
V
3.0
43
Replace the CDI
Replace the pulser
Loaded
1,500
3,500
3.0
17.0
29.5