ELEC
IGNITION SYSTEM
CHARGE COIL
1. Measure:
Charge coil resistance
Out of specification
Charge coil resistance:
Brown/White
(Br/W) – Black (B)
497.7 – 608.3 Ω at 20 C
(68 F)
PULSER COIL
1. Measure:
Pulser coil resistance
Out of specification
Pulser coil resistance:
White/Red (W/R) – Black (B)
12.6 – 15,4 Ω at 20 C
(68 F)
THERMO SWITCH
1. Measure
Thermo switch continuity
Out of specification
Thermo switch continuity
temperature:
Pink (P) – Black (B)
a 66 – 74 C (100.4 – 125.6 F)
b 57 – 43 C (93.2 – 78.8 F)
1 Discontinuity
2 Continuity
3 Discontinuity
Measurement steps:
Suspend thermostat in a vessel.
Place known reliable thermometer in
water.
Heat water slowly.
Observe thermometer, while stirring
water continually.
44
Replace.
Replace.
Replace.
A Temperature
B Time