Electrically Locking

L9080/LV9080 EL Electrically Locked

(Fail Safe):
Outside trim is continuously locked electrically. The
latchbolt is retracted by a key outside or by the knob/lever
inside. Switch or power failure allows the outside
knob/lever to retract the latchbolt. The auxiliary latch
deadlocks the latchbolt when the door is closed. The
inside knob/lever is always free for immediate exit.

L9080/LV9080 EU Electrically Unlocked

(Fail Secure):
Outside trim is unlocked electrically. The latchbolt is
retracted by a key outside or by knob/lever inside. The
auxiliary latch deadlocks the latchbolt when the door is
closed. The inside knob/lever is always free for
immediate exit.

Request to Exit (RX) Feature*:

A micro switch inside the lock case is activated when
the knob/lever is rotated. The switch signals the use of
that opening to security systems allowing a
non-disruptive means of immediate egress. Specify
L-Series lock case with L283-059 for normally closed or
L283-125 for normally open. Specify LV-Series lock
case with L283-197 for normally closed and L283-196
for normally open.
L-Series RX Switch
* Available on L9080EL, LV9080EL, L9080EU,
LV9080EU, L9010, L9050, LV9050, L9060, LV9060,
L9070, LV9070, L9071, LV9071, L9076, LV9076,
L9077,LV9077, L9080, LV9080, L9056, LV9056,
L9496, LV9496, L9453, LV9453, L9456, LV9456,
L9457, LV9457, L9082EL/EU
LV-Series RX Switch
L9082 EL or EU Electrically Locked or
Unlocked Both Sides:
The same as L9080EL/EU, except both knobs/levers are
locked or unlocked simultaneously.
(Previously XL11-452.)

Cylinders:

All Schlage cylinders are available with the previously
mentioned locks. Specify the locks with the required
cylinder code, e.g. L9080PEL (code P) for classic and full
®
size Everest
cylinders. For a complete list of order
codes, see "Ordering Procedures" on page 136.

Replacement Kit:

L283-053 Solenoid and Driver, EL or EU.

Electrical Requirements:

Voltage: 24V AC or 24V DC (max. 26V,min. 22V).
Peak Current: 1.3 Amps at 5 to 10 second intervals.
Holding Current: .135 Amps between peak current intervals.
Operating Temperature: Max +151° F, min. -31° F.
RX Micro Switch: 5 Amps, normally closed circuit.

Typical Installation:

All installations should be in accordance with local electrical
codes and National Electrical Code NFPA #70.
It is recommended that each lock have its own 24 volt
transformer. Two or more locks may be operated in
parallel from a single transformer provided it has the
necessary current rating. DO NOT connect locks in
series from a higher voltage rated transformer. Damage
to locks may occur if they connect to a supply circuit that
also contains electromagnetic devices. The transient
voltage must be suppressed at the equipment producing
them before connecting the locks to a circuit. A varistor
rated at 35 volts (at peak current) may be used for
transient voltage protection.
Install
varistor
here
if used
(not furnished)
Switch
(not furnished)
L
Service Manual
Solenoid
Operated
Lock
Frame to
Door Connector
(not furnished)
Transformer
(not furnished)
24V AC
110V AC
115