Summary of Contents for Brilliant Fires Limited 401B
Page 1
USER, INSTALLATION AND SERVICING INSTRUCTIONS Please read these instructions before installation and use Keep this booklet handy for future reference Brilliant 401B...
CONTENTS USER’S INSTRUCTIONS INSTALLER’S INSTRUCTIONS INSTALLATION FLUE SYSTEM INSTALLATION SETTING THE APPLIANCE WIRELESS REMOTE CONTROL COMMISSIONING AND SERVICING FAULT FINDING...
USER’S INSTRUCTIONS This user manual will give you the information Avoid contact with hot parts of the appliance to you need to operate the appliance properly and prevent burns. safely. DO NOT leave children, the elderly or infirm Carefully read this user manual prior to using alone with a burning appliance.
Page 4
Ignition, controlling the flame height and new batteries. switching off are performed by the remote When fitting the new batteries, ensure correct control that operates a receiver in the control polarity by referring to the polarity diagrams hatch. For some appliances, no control hatch is inside the battery compartment.
Page 5
Although highly improbable, we cannot rule out Although highly improbable, we cannot rule out Although highly improbable, we cannot rule out Although highly improbable, we cannot rule out MAN POSITION that your appliance’s ignition process can be that your appliance’s ignition process can be that your appliance’s ignition process can be that your appliance’s ignition process can be By briefly pressing the SET button on the...
Page 6
If you continue to hold down the The gas control is located in the control hatch (large flame) button on the remote or is placed under the appliance. control, the main burner should be Simultaneously press the OFF and (large largely ignited within about 10 flame) buttons on the remote control.
Page 7
Example: Example of switch times: Setting the TEMP function you can keep the You have set a day temperature and night day temperature in the room at 20 °C; while you temperature of, for example, 20 °C and 15 °C. use the TEMP function at night to maintain a TIMER = 7 hours;...
Page 8
SERVICING GUARANTEE Replacement parts are available from your Your Brilliant appliance is guaranteed for 12 supplier or through our mail order service. months from the date of purchase against faulty Always quote the product code and serial materials or workmanship. Please report any number when ordering new parts.
Page 9
INSTALLATION INSTRUCTIONS INTRODUCTION SITE REQUIREMENTS This fire is CE approved to the European Always place the appliance in front of a wall Standard EN 613 and meets the essential constructed from non-combustible materials or ® requirements of the Gas Appliance Directive. properly shielded using 12mm Supalux equivalent heat-resistant material.
Page 10
Table 1: Parts included with the delivery Table 1: Parts included with the delivery Table 1: Parts included with the delivery Table 1: Parts included with the delivery Only use the concentric flue pipe system supplied by Brilliant. This Part Part Quantity Quantity...
Page 11
Table 3: Determining permissibility of concentric flue system Table 3: Determining permissibility of concentric flue system Table 3: Determining permissibility of concentric flue system Table 3: Determining permissibility of concentric flue system Total No. of Total No. of meters vertical and/or sloping pipe length meters horizontal pipe length No bends...
INSTALLATION - (WITH OPTIONAL CONTROL HATCH) The gas control is mounted underneath the appliance. It must be taken out for fitting in the control hatch at a later time. Follow this procedure: Disconnect the pipes from the gas control (flexible gas pipe, aluminium pilot burner pipe and thermocouple 1);...
Page 14
Prior to completely closing the chimney breast, The pilot burner pipe should remain complete the flue system as described in permanently free from the ground and the walls Section D and ensure all clamps and fixing of the room in which the appliance is built in. brackets are securely fixed.
FLUE SYSTEM INSTALLATION Only use the concentric flue pipe When using a Wall Terminal Wall Terminal, the following Wall Terminal Wall Terminal system supplied by Brilliant. This applies: system has been tested in conjunction The maximum vertical pipe length can be with the appliance.
Page 16
On each connection, apply a clip binding with silicon sealing ring. Use a self-tapping screw to fix the clip binding to the pipe on locations that cannot be reached after installation. Apply sufficient wall brackets, so that the weight of the flue does not rest on the appliance. Determine the remaining length for the Wall Wall Wall...
SETTING THE APPLIANCE Unscrew the 8 self-tapping screws of the 3 GLASS PANEL panel clamps (C) from the frame and first Handle the glass panel with care to remove the lower clamp strip and then the side avoid damaging it when removing and clamp strips of the frame;...
Page 18
If the instruction in table 2 or 4 says to remove SETTING THE APPLIANCE the Air Inlet Guide, proceed as follows (See Fig The appliance has to be set in such a way that it works correctly in combination with the flue system configuration used.
Page 19
Fill the vermiculite tray with chips; spread the PLACING THE LOG FUEL EFFECT chips evenly (See Fig. E9). A fuel effect is supplied with the appliance and consists of chips and a number of logs. Identify the logs A up to H by using Fig. E10. Use the burn marks on the logs for identification.
WIRELESS REMOTE CONTROL The appliance is supplied with a wireless Insert 4 new AA AA batteries observing the correct remote control. orientation as shown in the battery compartment. Controlling the flame height, igniting and Replace the cover. switching off take place through a remote handset that controls a receiver.
Page 22
SETTING THE COMMUNICATION CODE Prior to putting the appliance into operation, a communication code must be set between the remote control and the receiver. If the receiver or the remote control are replaced, a new code will have to be set. Follow the procedure below: Fit the 9V PP3 battery into the remote handset as described in the User Manual...
COMMISSIONING AND SERVICING After igniting the pilot flame, the main burner COMMISIONING will ignite during the ignition procedure after In order to check whether the appliance is approx 25 seconds. working properly and safely, you must perform the following inspections before the appliance is Check whether the main burner continues to used.
Page 24
After opening the gas valve, the main burner If required, clean the following components: should burn within a few seconds. THE PILOT BURNER The space surrounding the pilot burner. When the gas valve is opened, the motor will start to run; this is audible. THE GLASS PANEL.
When the user starts the appliance for the first time, point out that; In order to avoid cracks in a chimney breast made of stone-like materials or finished with plaster, it should dry for at least 6 weeks prior to putting the appliance into operation. When the appliance is lit for the first time, volatile components evaporate from paint, and other constructional materials.
Page 26
FAULT FINDING: IGNITION AND BURNING Start Start Start Start 2.06 Pilot can be lit. 2.08 Does main burner Does it stay alight? ignite immediately? 2.01 Can Pilot be lit? 2.02 Sparking? 2.07 Check thermocouple thermocouple thermocouple thermocouple 2.09 Ignition procedure 2.09 Ignition procedure 2.09 Ignition procedure 2.09 Ignition procedure...
Page 27
2.10 Main burner(s) 2.12 Does appliance ignite smoothly and switch off 2.14 Does main burner 2.16 Is flame picture across the full length exactly 22 sec after go out after first ignition by servomotor starts after 'some time'? pilot burner? running? 2.11 No proper cross lighting 2.15 Check...
Page 28
Brilliant Fires Limited Thwaites Close Blackburn BB1 2QQ England tel +44 (0)1254 682384 fax +44 (0)1254 672647 www.brilliantfires.co.uk info@brilliantfires.co.uk 12 03 2013...
Need help?
Do you have a question about the 401B and is the answer not in the manual?