Brilliant Fires Limited SLAB 30 User, Installation And Servicing Instructions

Advertisement

S S S S
USER, INSTALLATION AND SERVICING
INSTRUCTIONS
Please read these instructions before installation and use
Keep this booklet handy for future reference
SLAB RANGE - LITHIUM BATTERY
the brilliant SLAB range

Advertisement

Table of Contents
loading

Summary of Contents for Brilliant Fires Limited SLAB 30

  • Page 1 S S S S USER, INSTALLATION AND SERVICING INSTRUCTIONS Please read these instructions before installation and use Keep this booklet handy for future reference SLAB RANGE - LITHIUM BATTERY the brilliant SLAB range...
  • Page 2 CONTENTS USER’S INSTRUCTIONS INSTALLER’S INSTRUCTIONS SLAB 30 & 22 FRAME 30, 22 & 22 INSET WALL 30 PANORAMA 30 VISION 30 HOLE-IN-WALL 30 LEDGE 30 & 22 STORM 22 GEOMETRY 30 & 22 PLACEMENT OF CERAMICS PEBBLE DRIFTWOOD AND CHARCOAL...
  • Page 3 USER’S INSTRUCTIONS - ALL VERSIONS MANUAL CONTROL VERSION TO REDUCE THE HEAT SETTING Turn the gas control knob anti-clockwise Manual control towards the low setting (small flame symbol). TO TURN THE FIRE OFF Low position High Depress the gas control knob slightly and turn position clockwise to the pilot position (spark symbol).
  • Page 4 TO LIGHT THE FIRE low setting. This is a normal characteristic of the control unit. Point the handset at the sensor on the fire, situated centrally underneath the raised hearth. Point the handset at the sensor on the fire. Push Press and hold the two buttons together on the and hold the small round button (marked with left hand side of the handset, when the fire...
  • Page 5: Important Notes

    ® When fitting a replacement battery ensure that 5. Any polish deposits on the Corian surfaces it is located as shown in figure A.2 or F.1 if the can be cleaned with Cif scouring cream. appliance is a Ledge. CLEANING THE CORIAN ®...
  • Page 6 PEBBLE BURNER CERAMICS VERSION As pebbles are light coloured, any soot discoloration may be more visible than on the other available fuel effects. WARNING The ODS must not be adjusted or put out of operation and only original manufacturer’s replacement parts must be used. A 100 cm2 air vent must be fitted.
  • Page 7 SPARES & SERVICE Replacement parts are available from your Only the following components are user supplier or through our mail order service. replaceable parts: Always quote the product code and serial number when ordering new parts. This All ceramic components. information is on the burner data badge.
  • Page 8: Technical Information

    INSTALLATION INSTRUCTIONS - ALL VERSIONS INTRODUCTION TECHNICAL INFORMATION NATURAL GAS (G20) This fire is CE approved to the European Standard EN 509 and is intended for decorative Heat Input Max (gross): 7.0 kW purposes. Heat Input Min (gross): 4.1 kW Inlet Pressure: 20 mbar The fire must be installed and serviced by a...
  • Page 9 BUILDERS OPENING AND HEARTH GAS SUPPLY The fire must be installed in a non-combustible The gas connection to the fire must be in 8mm builders opening, which must only have an copper pipe not more than 1.5 metres long and entrance through the fireplace opening and an in accordance with National Regulations.
  • Page 10 An optional flue gather with a 125mm spigot is A pre-cast concrete gas flue block system to BS available to enable direct connection to a 1289 Pt. 1 and Building Regulations Part J can 125mm flue liner or using an appliance be used (subject to suitability of the starter connector can be connected to a 125mm metal block).
  • Page 11 GLASS CANOPIES of the firebox. This is to prevent any damage to the glass whilst in transit. The three fixing If an appliance has been factory specified with a screws are packed attached to the canopy. glass canopy, the glass canopy must be fitted when installing the appliance.
  • Page 12 CANOPY NOT VISIBLE ABOVE THIS LINE CANOPY OPTIONS CANOPY VISIBLE BELOW THIS LINE SLAB 30 STD Steel not visible LEDGE 30 STD SLAB 30 NV Steel not visible LEDGE 30 NV WALL NV Glass visible PANORAMA NV VISION NV HOLE-IN-WALL NV...
  • Page 13 INSTALLATION - SLAB 30, SLAB 22 SLAB 30 SLAB 22 Mantle Fixing Bracket Mantle Fixing Holes Fixing Holes Raised Hearth Fixing Points Gas Inlet Raised Hearth Burner Fixing Points The mantle fixing bracket is screwed to the top Prepare the gas supply noting the entry point in of the box in its correct position and does not the rear of the box.
  • Page 14 FITTING THE MANTLE the fireplace opening using the screws provided. Refit the inlet closure plate. Remove all the remaining protective plastic coating from the firebox. Slide the raised hearth onto the raised hearth metal shelf and lightly secure with the two Ensure the firebox is properly sealed countersunk screws removed previously (see and fixed to the fireplace opening.
  • Page 15 INSTALLATION - FRAME 30, FRAME 22 FRAME 30 FRAME 22 FRAME 22 INSET Frame Locator strips Stainless Steel Frame Fixing Holes Raised Hearth Fixing Points Gas Inlet Raised Hearth Burner Fixing Points FRAME 22 FRAME 22 INSET FRAME 30 Use CENTRE CENTRE CENTRE CENTRE...
  • Page 16 GAS CONNECTION Partially peel the protective plastic coating away from the metal box anywhere it may become MANUAL CONTROL VERSION trapped. Cut a 70mm length of copper pipe and attach it Apply a thin bead of silicon sealant around the to the isolating tap supplied.
  • Page 17 INSTALLATION - WALL, PANORAMA, VISION, HOLE-IN-WALL WALL PANORAMA VISION HOLE-IN WALL Fixing Holes Securing Screws H.I.W. Gas Inlet Mantle Hanging Bracket Raised Raised Hearth Hearth Fixing Points Burner Fixing Points...
  • Page 18 The mantle fixing bracket is screwed to the top Slide the raised hearth onto the raised hearth of the box in its correct position and does not metal shelf and lightly secure with the two need to be removed. Remove the four screws countersunk screws removed previously (see that secure the burner to the box, two at the diagram E.1).
  • Page 19 INSTALLATION - LEDGE 30, LEDGE 22 LEDGE 30 LEDGE 22 Fixing Holes Battery Lead Through Hole Burner Fixing Points Battery Position IR Sensor Lead Position 2 Screws IR Sensor and Bracket LEDGE 30 A - Locate Bracket In Slot Align Plugs B - Push Back C - Tighten Screw Press Together...
  • Page 20 Remove the four screws that secure the burner the base of the box (see diagrams F.1 and F.3). to the box, two at the base of the front leg and Fit the IR Sensor Bracket to the bottom of the two at the top of the rear sloping plate.
  • Page 21 INSTALLATION - STORM 22 Frame Tensioning Holes Data Badge Burner Fixing Battery Position (Roof of Box) Points Fixing Holes Frame Height Adjustment Gas Inlet Centralise inner flanges of the frame on the sides of the Ensure correct raised hearth positioning of IR sensor cable in slot IR sensor bracket fixing screws (2)
  • Page 22 GAS CONNECTION Remove the four screws that secure the burner to the box, two at the base of the front leg and Note the position of the isolating tap and two at the top of the rear sloping plate. Remove disconnect it.
  • Page 23 INSTALLATION - GEOMETRY 30, GEOMETRY 22 GEOMETRY 30 GEOMETRY 22 Corian ® Surround Box Fixing Screws Clearance Remove Frame ® Corian Surround Fixing Screws (4) Locator strips Magnet Flange Stainless Steel Frame Use CENTRE CENTRE CENTRE CENTRE Holes This range of fires use either the FRAME 30 or holes that fit over the box fixing screws.
  • Page 24 PLACEMENT OF CERAMICS - PEBBLE Underbed MUST SIT BEHIND THESE TABS ON THE BURNER Front Piece Curved Flange 1. Locate the base of the front ceramic piece 2. Holding the underbed by the top rear, up against the brackets at the front edge, position it against the front ceramic piece.
  • Page 25 PLACEMENT OF CERAMICS - DRIFTWOOD AND CHARCOAL Underbed MUST SIT BEHIND THESE TABS ON THE BURNER Front Piece Curved Flange 1. Locate the base of the front ceramic piece 2. Holding the underbed by the top rear, up against the brackets at the front edge, position it against the front ceramic piece.
  • Page 26 PLACEMENT OF CERAMICS - OUTER CERAMICS 10 Numbered Outer Clusters 2 Loose Outer pieces marked “X” on underside Place the numbered outer ceramic clusters into Ensure the outer ceramics are evenly spaced Ensure the outer ceramics are evenly spaced Ensure the outer ceramics are evenly spaced Ensure the outer ceramics are evenly spaced the gap around the burner starting with number and do not overlap or interfere with burner...
  • Page 27 PLACEMENT OF CERAMICS - DISH PEBBLE Outer Pebbles 12 Pieces Dish 1. The Dish is designed to fit over the existing 2. Place the 12 small pebbles evenly around ceramics. Position the Dish over the the edge of the dish to complete the effect. ceramics and slowly lower into position.
  • Page 28 COMISSIONING AND SERVICING COMISSIONING SERVICING Remove all plastic protective films. Carefully remove the outer ceramics and place to one side. The LEDGE and STORM products require commissioning to be carried out prior to fitting Carefully remove the burner ceramics and place the surround / frame.
  • Page 29 [Blank]...
  • Page 30 [Blank]...
  • Page 31 [Blank]...
  • Page 32 Brilliant Fires Limited Thwaites Close Blackburn BB1 2QQ England tel +44 (0)1254 682384 fax +44 (0)1254 672647 LFL Group Limited . Thwaites Close . Blackburn BB1 2QQ . England www.brilliantfires.co.uk Tel 01254 682384 . Fax 01254 672647 . www.brilliantfires.co.uk . info@brilliantfires.co.uk info@brilliantfires.co.uk...

Table of Contents