Brilliant Fires Limited ROMANCE User, Installation And Servicing Instructions

Advertisement

USER, INSTALLATION AND SERVICING
INSTRUCTIONS
Please read these instructions before installation and use
Keep this booklet handy for future reference
the brilliant FIRE range
the brilliant Romance
RO
RO
RO
RO
ROMANCE

Advertisement

Table of Contents
loading

Summary of Contents for Brilliant Fires Limited ROMANCE

  • Page 1 USER, INSTALLATION AND SERVICING INSTRUCTIONS Please read these instructions before installation and use Keep this booklet handy for future reference ROMANCE the brilliant FIRE range the brilliant Romance...
  • Page 2 CONTENTS USER’S INSTRUCTIONS INSTALLER’S INSTRUCTIONS ROMANCE PLACEMENT OF CERAMICS PEBBLE AND COAL DRIFTWOOD AND CHARCOAL COMMISIONING AND SERVICING...
  • Page 3 USER’S INSTRUCTIONS - ALL VERSIONS MANUAL CONTROL VERSION REMOTE CONTROL VERSION The gas control is situated centrally behind the Remote control control cover. Piezo ignition is used to light the pilot, which can also be lit with a match. The pilot is designed to remain permanently on, enabling the fire to be lit by simply turning the Battery Connection...
  • Page 4 or keep pressing to lower slowly then release Before reporting a fault on your fire the button at the desired position. ensure the battery is in good condition (i.e. single beep) CAUTION TO INCREASE THE HEAT SETTING Point the handset at the sensor on the fire. Always dispose of used batteries in accordance Press and hold the plus button (marked with a with the local authority regulations.
  • Page 5: Important Notes

    CLEANING The fire is fitted with an Oxygen Depletion Sensor (ODS) which continuously monitors the Cleaning the fire should only be atmosphere in the room turning off the gas carried out when the fire is turned off supply to the fire if combustion products are and is cold.
  • Page 6 excessive quantities of soot or debris on the fire DIAGNOSTIC INFORMATION - AUTO VERSION will require removal, refer to “CLEANING“. If a The control box will sound beeps to indicate the sooting problem persists seek expert advise. current condition of the burner system as outlined in the table below:- The appliance must be checked periodically for soot/ debris that has fallen from the chimney...
  • Page 7 [Blank]...
  • Page 8: Technical Information

    INSTALLATION INSTRUCTIONS - ALL VERSIONS INTRODUCTION TECHNICAL INFORMATION This fire is CE approved to the European NATURAL GAS (G20) Standard EN 509 and is intended for decorative 16/18 Standard 16/18 High purposes. Heat Input Max (gross): 7.0 kW 9.0kW Heat Input Min (gross): 4.1 kW 4.4kW The fire must be installed and serviced by a...
  • Page 9: Site Requirements

    The chimney/flue must be class 1 and must have a height of at least 3m with an internal diameter of not less than 175mm (Romance 16” Standard versions are approved for use with a 125mm class 2 liner or terminal). Any damper or register plate must be removed or locked open.
  • Page 10: Gas Connection

    INSTALLATION - ROMANCE Burner Fixing Points Hearth Plate Fixing Holes Data Label Manual Version Auto Version Isolating Tap Isolating Tap Battery Position Control Knob Appliance Buttons IR Sensor GAS CONNECTION PREPARE THE FIREBOX Remove the three screws that secure the...
  • Page 11 the following instructions and refer to Figures Replace the screw and tighten whilst holding C.3 and C.4. the Knob and Heat Shields in the correct orientation. The Control Knob Heat Shield is only used on Manual burner trays. Remove the Knob from the Controls Cover by using a screwdriver to remove the screw at the rear.
  • Page 12 PLACEMENT OF CERAMICS - PEBBLE AND COAL Underbed MUST SIT BEHIND THESE TABS ON THE BURNER Front Piece 1. Locate the base of the front ceramic piece 2. Holding the underbed by the top rear, up against the brackets at the front edge, position it against the front ceramic piece.
  • Page 13 PLACEMENT OF CERAMICS - DRIFTWOOD AND CHARCOAL Underbed MUST SIT BEHIND THESE TABS ON THE BURNER Front Piece 1. Locate the base of the front ceramic piece 2. Holding the underbed by the top rear, up against the brackets at the front edge, position it against the front ceramic piece.
  • Page 14 COMISSIONING AND SERVICING COMISSIONING SERVICING Ensure all plastic protective films have been Carefully remove the burner ceramics and place removed. to one side, do not mix with outer ceramics. Ensure the Isolating tap is fully open and check Locate the isolating tap and turn the gas off. for gas leaks.
  • Page 15 [Blank]...
  • Page 16 Brilliant Fires Limited Thwaites Close Blackburn BB1 2QQ England tel +44 (0)1254 682384 fax +44 (0)1254 672647 www.brilliantfires.co.uk info@brilliantfires.co.uk 15 11 2010...

Table of Contents