CODE
Safety Data Faults
1
Unconfigured safety data
2
Waiting for safety data verification
Internal Operation Errors
3
Internal fault: Hardware fault
4
Internal fault: Safety Relay key feedback error
5
Internal fault: Unstable power (DCDC) output
6
Internal fault: Invalid processor clock
7
Internal fault: Safety relay drive error
8
Internal fault: Zero crossing not detected
9
Internal fault: Flame bias out of range
10
Internal fault: Invalid Burner control state
11
Internal fault: Invalid Burner control state flag
12
Internal fault: Safety relay drive cap short
13
Internal fault: PII shorted to ILK
14
Internal fault: HFS shorted to LCI
15
Internal fault: Safety relay test failed due to
feedback ON
16
Internal fault: Safety relay test failed due to safety
relay OFF
17
Internal fault: Safety relay test failed due to safety
relay not OFF
18
Internal fault: Safety relay test failed due to
feedback not ON
19
Internal fault: Safety RAM write
20
Internal fault: Flame ripple and overflow
21
Internal fault: Flame number of sample mismatch
22
Internal fault: Flame bias out of range
23
Internal fault: Bias changed since heating cycle
starts
24
Internal fault: Spark voltage stuck low or high
25
Internal fault: Spark voltage changed too much
during flame sensing time
26
Internal fault: Static flame ripple
27
Internal fault: Flame rod shorted to ground
detected
28
Internal fault: A/D linearity test fails
29
Internal fault: Flame bias cannot be set in range
60

TROUBLESHOOTING CODES

TABLE 12. TROUBLESHOOTING CODES
DESCRIPTION
Servicing should only be performed by a Qualified Service Agent
RECOMMENDED TROUBLESHOOTING OF
LOCKOUT CODES
1.
New Device, complete device configuration and
safety verification.
2.
If fault repeats, replace module.
1.
Device in Configuration mode and safety
parameters need verification and a device needs
reset to complete verification.
2.
Configuration ended without verification, re enter
configuration, verify safety parameters and reset
device to complete verification.
3.
If fault repeats, replace module.
Internal Fault.
1.
Reset Module.
2.
If fault repeats, replace module.
NOTE
L
L
H
H
H
H
H
H
H
L
L
H
H or L
H or L
L
L
L
L
L
H
H
H
H
H
H
H
H
H
H

Hide quick links: