Helmer i. Series Operation Manual

Helmer i. Series Operation Manual

Undercounter
Hide thumbs Also See for i. Series:

Advertisement

Laboratory
i.Series
iLR105-GX
Horizon Series
HLR105-GX
Pharmacy
i.Series
iPR105-GX
Horizon Series
HPR105-GX
Blood Bank
i.Series
iBR105-GX
Horizon Series
HBR105-GX
Refrigerator Operation Manual
®
i.Series
and Horizon Series™ - Undercounter
360397/A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the i. Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Helmer i. Series

  • Page 1 Refrigerator Operation Manual ® i.Series and Horizon Series™ - Undercounter Laboratory i.Series iLR105-GX Horizon Series HLR105-GX Pharmacy i.Series iPR105-GX Horizon Series HPR105-GX Blood Bank i.Series iBR105-GX Horizon Series HBR105-GX 360397/A...
  • Page 2 , Horizon Series™, and Rel.i™ are registered trademarks or trademarks ® of Helmer, Inc. in the United States of America. All other trademarks and registered trademarks are the property of their respective owners. Helmer, Inc., doing business as (DBA) Helmer Scientific and Helmer.
  • Page 3: Table Of Contents

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Contents About this Manual ....................4 Intended Audience .
  • Page 4 Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Horizon Series™ Operation ..................17 6.1 Initial Power Up .
  • Page 5: About This Manual

    Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Helmer refrigerators are intended for the storage of blood products and other medical and scientific products. Safety Symbols and Precautions...
  • Page 6 Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Symbols and Labels found on the units The following symbols may be found on the refrigerator or refrigerator packaging: Caution: Risk of damage to equipment or Earth / ground terminal...
  • Page 7: Avoiding Injury

    ♦ The refrigerator is not considered to be a storage cabinet for flammable or hazardous materials. ♦ Use caution when moving a stacked configuration. CAUTION Decontaminate parts prior to sending for service or repair. Contact Helmer Scientific or your distributor for decontamination instructions and a Return Authorization Number. General Recommendations General Use Allow refrigerator to come to room temperature before switching power on.
  • Page 8: Installation

    • Do not open multiple loaded drawers at the same time. • Do not lean on or push down on an open door or extended drawers. Contact Helmer or your distributor for more information regarding the stacking kit and methods to secure both units to the wall and/or floor.
  • Page 9: Temperature Probes

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Temperature Probes A solid ballast or probe bottle and container of glycerin have been provided with this unit. The glycerin is used to create a solution which, when placed in the probe bottle, simulates the product stored in the refrigerator. The product simulation solution temperature reflects the product’s temperature during normal operation.
  • Page 10 Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Prior to use: Route the chart recorder probe through the rear access port and place in bottle with primary monitor probe, or install in ballast and secure with thumb screw.
  • Page 11: I.series ® Operation

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® i.Series ® Operation Initial Power-up 1. Plug the power cord into a grounded outlet that meets the electrical requirements on the product specification label. 2. Switch AC ON/OFF switch ON.
  • Page 12: Operation

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Operation Notes • Refer to the i.C User Guide for complete information regarding the i.C User Interface. • The i.C Home screen displays temperature and alarm information, and provides icons to gain access to other functions of the i.C...
  • Page 13: Set Alarm Parameters

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Set Alarm Parameters > > Enter the Settings password. Scroll down to select Alarm Settings. Touch minus (-) or plus (+) on spin box to set each alarm parameter.
  • Page 14: Active Alarms

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Active Alarms Home screen with active alarm Table 1. Active Alarms Alarm Description Communication Failure 1 Communication lost between i.C display board and control board Configuration file is corrupt or i.C...
  • Page 15 Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Application Icon Table Image Name Image Name Image Name Image Name Home Temperature Graph PDF Download Save Event Log Alarm Test Upload Cancel Mute Information Logs Access Control...
  • Page 16: Min/Max Temperature Monitoring

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Min/Max Temperature Monitoring The Min/Max temperature display provides the highest and lowest Primary Monitor probe temperature reading since the last system reset (power-on event) or manually-initiated reset. Touch the Reset icon to the right of the display to manually reset.
  • Page 17: I.series ® Access Control (Optional)

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® i.Series ® Access Control (Optional) Allows user-specific secure access to the refrigerator. Notes • During a power failure, the optional Access Control lock will remain locked until battery power is depleted or until the back-up battery key switch is switched OFF.
  • Page 18: Horizon Series™ Operation

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Horizon Series™ Operation 6.1 Initial Power Up 1. Plug the power cord into a grounded outlet that meets the electrical requirements on the product specification label. 2. Switch AC ON/OFF switch ON.
  • Page 19 Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® View recorded temperature timer Notes • The timer denotes the period of time that has elapsed. It does not display the time at which a minimum or maximum temperature occurred.
  • Page 20: Set Parameter Values

    5. Release SET button. The new setting is saved. 6. Press and hold the Up and Down Arrows simultaneously for 3 seconds to exit program mode. Note Contact Helmer Technical Service to set Rail Limit values. Table 2. Parameter Values Parameter...
  • Page 21: Active Alarms

    This should not be adjusted from the original setting unless directed by Helmer Technical Service. The Upper and Lower Rail Limits help control the refrigeration based on the control probe temperature reading and the set point. These limit values should not be changed from the default setting unless directed by Helmer Technical Service. NOTICE Control Sensor Offset and Rail Limits are factory-preset and should not be changed.
  • Page 22: Horizon Series™ Access Control (Optional)

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Horizon Series™ Access Control (Optional) Allows user-specific secure access to the refrigerator. Notes • During a power failure, the optional Access Control lock will remain locked until battery power is depleted or until the back-up battery key switch is switched OFF.
  • Page 23: Product Specifications

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Product Specifications Operating Standards These units are designed to operate under the following environmental conditions: ♦ Indoor use only ♦ Altitude (maximum): 2000 m ♦ Ambient temperature range: 15 °C to 32 °C ♦...
  • Page 24 Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Table 5. Refrigerator Specifications Dimensions W x H x D in. (mm) Net Wt. Cu. Ft/ lbs (kg) Model Voltage Code Amps* Liters Cabinet Door Exterior* 115V 60 Hz 24 x 31.9 x 28.1...
  • Page 25: Compliance

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Compliance Safety Compliance This device complies with the requirements of directive 93/42/EEC concerning Medical Devices, as amended by 2007/47/EC. 0086 This product is certified to applicable UL and CSA standards by a NRTL.
  • Page 26: Appendix A: Parts

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Appendix A: Parts i.Series Parts Letter Description Letter Description user interface Remote alarm contacts Backup battery key switch RJ45 Ethernet port AC On/Off switch USB Port Battery switch...
  • Page 27: Appendix B: Parts

    Helmer Scientific i.Series and Horizon Series™ Refrigerator - Undercounter Operation Manual ® Appendix B: Parts Horizon Series Parts Letter Description Letter Description Temperature Chart Recorder Door switch Display board Remote alarm contacts Backup battery key switch AC output power cord receptacle...
  • Page 28 Helmer Scientific 14400 Bergen Boulevard, Noblesville, IN 46060 USA 360397/A Copyright © 2019 Helmer, Inc.

Table of Contents