End of Line and PM Test
Functional Test for Reservoir Purge Valve (RPV)
Step 1 Install Panel System with Reservoir Purge Valve (RPV).
Step 2 Start engine or use shop air to build system pressure in reservoir air
tank to 110 - 120 PSI.
Step 3 Check for any air leaks.
Step 4 Set parking brakes or remove emergency airline from the trailer.
There will be a blast of air coming from the exhaust tube that will last
for about eight seconds. Check for any moisture/contaminates during purge.
Step 5 Repeat Steps 1 through Step 4 for three to five cycles.