Heathrow Scientific Gusto Instruction Manual

High-speed mini-centrifuge
Hide thumbs Also See for Gusto:

Advertisement

Quick Links

High-Speed
Mini-Centrifuge
Instruction Manual
Instruction Manual ..................................... x
Manuel d'instructions ................................. x
Manual de Instrucciones ........................... x
Bedienungsanleitung ................................. x
pms 421
All rights reserved. Printed in China.
Tous droits réservés. Imprimé en Chine.
Todos los derechos reservados. Impreso en Chine.
Alle Rechte vorbehalten. Gedruckt in China.
#26-015-10050/51-483
1
©Heathrow Scientific
LLC
®
1.800.561.8187
information@itm.com
www.
.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gusto and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heathrow Scientific Gusto

  • Page 1 Manual de Instrucciones ......x Bedienungsanleitung ......... x pms 421 All rights reserved. Printed in China. Tous droits réservés. Imprimé en Chine. Todos los derechos reservados. Impreso en Chine. Alle Rechte vorbehalten. Gedruckt in China. #26-015-10050/51-483 ©Heathrow Scientific ® 1.800.561.8187 information@itm.com www. .com...
  • Page 2: Safety Precautions

    If there is a failure during the warranty period, not use materials with a density greater than 1.2g/cm. contact Heathrow Scientific® LLC for warranty service. Observe general laboratory safety precautions and regulations when 29. Do not attempt to use units that have not been correctly installed or using this product.
  • Page 3: Technical Data

    EC Declaration of Conformity Manufacturer: Heathrow Scientific ® Technical Data Address: 620 Lakeview Parkway • Vernon Hills, IL 60061 USA European Contact: Emergo Europe Molenstraat 15, 2513 BH, The Hague, The Netherlands Supplied Equipment: This unit has been constructed and conforms to the following: Safety Standards: •...
  • Page 4: Operation

    Front Panel with little or no vibration, the mini-centrifuge is ready to use. If there are loud or unusual sounds, or excessive vibration, DO NOT OPERATE. Contact Heathrow Scientific ® LLC Technical Support. At the set time, the rotor will spin down, stop and the unit will emit a beep when the cycle is complete.
  • Page 5: Troubleshooting

    Quick Spin Operation: Trouble Shooting Prepare the unit for centrifugation as in the General Operation (section above Steps 1-8). Press Quick Spin button (rotor should spin up to the set speed). The timer will begin counting. Once enough time has elapsed for your needs, release the Quick Trouble Resolution Spin button.
  • Page 6: Maintenance

    1.5mL / 2.0 mL Circular Rotor Maintenance 2 Tubes 3 Tubes 4 Tubes 6 Tubes 8 Tubes Your mini-centrifuge is normally maintenance-free. Clean unit only when it is not plugged into an electrical outlet. When necessary, the housing and rotor can be wiped using a damp cloth and a mild, non-corrosive detergent.
  • Page 7: Return For Repair

    If you believe that there is a defect in the product, you must, during the warranty period, notify Heathrow Scientific LLC, ® provide proof of purchase, and return the product to Heathrow Scientific LLC with a Return Authorization form.

Table of Contents