Installing Models Ctlp, Cts, Ctw; Connecting The Water Supply - Dometic CT4050 Installation Manual

Sanitation cassette toilets
Hide thumbs Also See for CT4050:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Installing the toilet
5.5

Installing models CTLP, CTS, CTW

These models have a wall connection console. The control and operating panel is
integrated in the wall connection console.
Models CTLP4xxx and CTS4xxx have no water tank, while model CTW4xxx has an
integrated water tank.
Setting up toilets CTLP4xxx, CTS4xxx, CTW4xxx
Set up all models with wall connection console directly against the room wall
(fig. g, page 13). A previously attached wall bracket is used to secure the toilet
and the wall bracket.
➤ Screw on the wall bracket, level, at the following height (fig. h, page 13):
– CTLP4050, CTLP4110: h = 479.5 mm
– CTS 4050, CTS4110: h = 651.5 mm
– CTW4050, CTW4110: h = 651.5 mm
➤ Put the entire toilet module into the desired position in front of the wall bracket.
➤ Lift the toilet and hook the housing into the wall bracket (fig. g, page 13).
➤ Tightly fasten the base plate with six bolts (fig. a, page 10).
➤ Slide in the mobile tank cassette (fig. f, page 12).
5.6

Connecting the water supply

A
NOTICE!
• The water supply is connected using a solenoid valve mounted in the
toilet housing (fig. i 1, page 14).
• The operating pressure (water pressure) of the solenoid valve should
not exceed 6 bar.
• The solenoid valve is damaged by excessive pressure.
I
NOTE
For the CTW4xxx models with an integrated water tank, the water
connection is installed at the factory.
➤ Use a spring band hose clamp to attach the freshwater supply hose to the
connection socket (fig. i 2, page 14).
➤ Perform a leak test.
28
CT4000
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct4110Ctlp4050Ctlp4110Ctw4110Ctw4050Cts4050 ... Show all

Table of Contents