7. OPERATING AND TESTING YOUR SMOKE ALARM
Sound Emitted
Normal
None
Operation
Test
3 long beeps repeated
twice
Alarm
3 long beeps, repeating "FIRE, FIRE!"
Low Battery
Single chirp every 60
seconds
Hush
See NOTE 1
Hush
Cancellation
Fault Mode
Single chirp every 30
seconds
End of Life
2 chirps every 30 sec-
See NOTE 2
onds
Note 1 – Pressing the Test/Hush bu on will desensi ze the alarm for 10 minutes to a known alarm condi on such as burnt toast.
During this period the LED flashes every 10 seconds.
Note 2 – Pushing the Test/Hush bu on at end of life silences End of Life chirps for 3 days. Can be used 10 mes within 30 days.
Allows the homeowner to purchase a replacement alarm.
2015.12.3
Voice Prompt
LED (all) & Escape Light
(Model WFPV)
(Model WFPL)
None
Flashes once every 10 minutes
"FIRE, FIRE!"
Flashes with alarm pattern
(Model WFPL briefly
illuminates amber safety light)
3 x flashes, synchronised with audi-
ble alarm (and illumination of amber
safety light for model WFPL)
"Low Battery"
Flashes once every 30 seconds
"Hush Mode Activated"
Flashes every 10 seconds for 10
minutes
"Hush Mode Cancelled"
Fault Code (2-12 flashes every
30 seconds)
Flashes twice every 30 seconds
2:55 PM
Page 8
Note
LED will flash every 60seconds for 10
minutes after power-up, then flashes
every 10 minutes
None
Identify source of smoke and
evacuate if necessary
Deactivate the alarm and replace
within 7 days
Cancelled by pressing test button