DESCRIPTION
The MN291 (Catalog #2115.84) is the latest in compact AC Current probes. Designed to meet the most
stringent demands in industry and electrical contracting, it also meets the latest safety and performance
standards. The probe has a measurement range up to 240Arms which makes it the perfect tool for
measurement with DMMs without AC range, recorders. The Model MN291 is compatible with any DC
voltmeter, multimeter, or other voltage measurement instrument that is capable of displaying 100mV of
output per amp of measured current, voltmeter accuracy of 0.75% or better and an input impedance of ≥
1MΩ.
WARNING
The safety warnings are provided to ensure the safety of personnel and proper operation of the
instrument. Read the instruction completely.
• Use caution on any circuit: potentially high voltages and currents may be present and may pose
a shock hazard.
• Do not use the probe if damaged. Always connect the current probe to the measuring device
before it is connected around the conductor
• Do not use on non-insulated conductor with a potential to ground greater than 600V CAT III
pollution 2. Use extreme caution when clamping around bare conductors or bus bars.
• Before each use, inspect the probe; look for cracks in housing or output cable insulation.
• Do not use clamp in wet environment or in locations that hazardous gases exist.
• Do not use the probe anywhere beyond the tactile barrier.
INTERNATIONAL ELECTRICAL SYMBOLS
This symbol signifies that the current probe is protected by double or reinforced insulation. Use
only factory specified replacement parts when servicing the instrument.
This symbol signifies CAUTION! and requests that the user refer to the user manual before
using the instrument.
This is a type A current sensor. This symbol signifies that application around and removal from
HAZARDOUS LIVE conductors is permitted.
DEFINITION OF MEASUREMENT CATEGORIES
CAT I: For measurements on circuits not directly connected to the AC supply wall outlet such as
protected secondaries, signal level, and limited energy circuits.
CAT II: For measurements performed on circuits directly connected to the electrical distribution system.
Examples are measurements on household appliances or portable tools.
CAT III: For measurements performed in the building installation at the distribution level such as on
hardwired equipment in fixed installation and circuit breakers.
CAT IV: For measurements performed at the primary electrical supply (<1000V) such as on primary
overcurrent protection devices, ripple control units, or meters.
RECEIVING YOUR SHIPMENT
Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify
your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately
with the carrier and notify your distributor at once, giving a detailed description of any damage.

Advertisement

loading

Summary of Contents for AEMC MN291

  • Page 1 User Manual DESCRIPTION The MN291 (Catalog #2115.84) is the latest in compact AC Current probes. Designed to meet the most stringent demands in industry and electrical contracting, it also meets the latest safety and performance standards. The probe has a measurement range up to 240Arms which makes it the perfect tool for measurement with DMMs without AC range, recorders.
  • Page 2 Barrier (keep hands below this barrier) Black 2.00" (51 mm) MN290 MN291 .1.18" (30 mm) ELECTRICAL SPECIFICATIONS Phase Shift: Not applicable (*Reference conditions: 18°C to 28°C, 20 to 75% RH, Nominal Range: 200A external magnetic field <40 A/m, 48 to 65 Hz sine wave, Measurement Range: 0.5 to 240A...
  • Page 3: Safety Specifications

    One Ø 0.78" (20 mm), bus bar 20 x 5mm ORDERING INFORMATION Case Protection: AC Current Probe MN290 ....Cat #2115.83 IP 40 (IEC 529) AC Current Probe MN291 ....Cat #2115.84 Drop Test: Accessories: Test per IEC 68-2-32: 1.0 m drop on 38 mm of Oak on concrete.
  • Page 4 This warranty is void if the unit has been tampered with, abused ® or if the defect is related to service not performed by AEMC Instruments. Full warranty coverage and product registration is available on our website at: www.aemc.com/warranty.html.