KEYPAD FUNCTIONS

On/Off switch
This illuminated switch is the main power switch for the
controller. It must be "ON" for the straightener to function.
Reset switch
This is the main circuit breaker for the straightener.
Run/Stop/Jog
In the Run mode, if the dancer arm is moved the pinch rolls
and lower straightening rolls will turn.
In the Jog mode, the jog button has to be depressed for the
rolls to turn. Jog function is used mainly for setup.
In the Stop mode there is no movement of the rolls.
Loop arm/external switch
When using a dancer arm, select loop arm button to display
"LV" for vertical. This button will also allow you to select
"LH" for horizontal. ("LH" is used for Pallet Master decoilers
only)
When using an external loop control, select external loop to
display "RT" for RTB or "RS" for RS2.
Note: Remote interface port "D" connector, if used, communicates
with external loop control.
Warning! - Never plug any type of computer or non Rapid-Air
equipment into this plug or severe damage will result.
Consult factory when installing new external controls.