Technical specifications
Slave type
Operational voltage in accordance
with AS-Interface specification in V
Total current input in mA
Input connection
Inputs
• Sensor supply via AS-Interface
• Sensors
• Voltage range in V
• Current carrying capacity for all in-
puts
(T
40 °C) in mA
u
• Switching level High in V
• Input current Low/High in mA
• Pin assignments for inputs
Outputs
• Type of output
• Current carrying-capacity
DC 12/13 typically
(max. 4 A per module) in A
• Maximum summation current
per module in A
• Pin assignments for outputs
• Short-circuit protection
• Inductive interference protection
• External voltage supply
DC 24 V
• Watchdog
I/O configuration
ID/ID2 code
Assignment of data bits
• Socket 1 (data bit D0)
• Socket 2 (data bit D1)
• Socket 3 (data bit D2)
• Socket 4 (data bit D3)
• Socket 5 (data bit D0)
• Socket 6 (data bit D1)
• Socket 7 (data bit D2)
• Socket 8 (data bit D3)
4 inputs/4 outputs IP68 / IP69K
Standard assignment
3RK1 400–1CR00–0AA3
Standard slaves
26.5 to 31.6
270
PNP
Short-circuit and overload proof
2- and 3-wire
20 to 30
200
³
10
³
1.5 /
6
PIN 1 = Sensor supply L+
PIN 2 = Data input I
PIN 3 = Sensor supply L-
PIN 4 = Data input I
PIN 5 = Ground connection
Electronics
2
4
3 = „-"
4 = Output
5 = Earth connection
built-in
built-in
Shared round cable connection
with AS-Interface connection via
M12 socket connector
built-in
7
0/F
PIN2/4 = IN1(D0)
PIN2/4 = IN2(D1)
PIN2/4 = IN3(D2)
PIN2/4 = IN4(D3)
PIN4 = OUT1(D0)
PIN4 = OUT2(D1)
PIN4 = OUT3(D2)
PIN4 = OUT4(D3)
AS-Interface Slaves
I/O modules for operation in the field
Digital I/O modules IP68 / IP69K - K60R
AS-Interface certificate
Approvals
Degree of protection
Earth connection
Ambient temperature in °C
Storage temperature in °C
Number of I/O sockets
Status indications
• I/O indication
• IndicationU
Help
• AS-Interface/diagnostics
indication
Conductor
Note 1
Note 2
4 inputs/4 outputs IP68 / IP69K
Standard assignment
3RK1 400–1CR00–0AA3
Yes
UL, CSA, ship building
IP68 / IP69K with mounting plate
3RK1 901-0CA00
IP68 test conditions see Section
Overview / Tests IP68 / IP69K
The degree of protection is only
achieved if all M12 connections
are tightened with the correct
torque. I/O sockets which are not
required must be covered with
sealing caps 3RK1 901-1KA00.
PIN5 of each M12 socket is
connected to the grounding plate
in the mounting plate via a pin.
-25 to +85
-40 to +85
8
Yellow LED
Green LED
Green/red LED
via mounting plate for K60
compact module
All K60 compact modules are
supplied with stainless steel
screws/sockets
To supply the output circuit,
an external supplementary
supply (AUX POWER)
of 20 to 30 V DC is necessary.
The supplementary supply must
comply with VDE 0106 (PELV),
safety class III.