Toshiba RAS-10N3ACV Series Owner's Manual page 2

Hide thumbs Also See for RAS-10N3ACV Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
PRECAUTIONS FOR SAFETY
• Do not install, repair, open or remove the cover. It may expose you
to dangerous voltages. Ask the dealer or the specialist to do this.
• Turning off the power supply will not prevent potential electric
0
shock.
• The appliance shall be installed in accordance with national wiring
DANGER
regulation.
• Means for disconnection from the supply having a contact
separation of at least 3 mm in all poles must be incorporated in
the fi xed wiring.
• Do not expose your body directly to cool air for a long time.
• Do not insert your fi nger or any article into the air inlet/outlet.
• When an abnormality (burning smell, etc.) occurs, stop the air
conditioner and disconnect the power supply or turn off the
breaker.
• This appliance is not intended for use by persons (including
0
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
WARNING
person responsible for their safety.
• Children should be supervised to ensure that they do not play with
the appliance.
• Do not use any refrigerant different from the one specifi ed for
complement or replacement. Otherwise, abnormally high pressure
may be generated in the refrigeration cycle, which may result in a
failure or explosion of the product or an injury to your body.
• Do not wash the unit with water. It may cause an electric shock.
• Do not use this air conditioner for other purposes such as
preserving food, breeding animal, etc.
• Do not step or put anything on the indoor/outdoor unit. It may
cause an injury or damage the unit.
• Do not touch aluminium fi n because it may cause an injury.
0
• Before cleaning the unit, turn off the main switch or the circuit
breaker.
CAUTION
• When the unit won't be used for a long time, turn off the main
switch or the circuit breaker.
• It is recommended that maintenance be performed by a specialist
when the unit has been operated for a long time.
• The manufacturer shall not assume any liability for the damage
caused by not observing the description of this manual.
1
INDOOR UNIT DISPLAY
CLEANING
RESET
TIMER
OPERATION
3
2
1
2
PREPARATION BEFORE USE
Preparing Filters
1. Open the air inlet grille and remove the air fi lters.
2. Attach the fi lters. (see detail in the accessory sheet).
Loading Batteries
1. Remove the slide cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Clock Setup
1. Push
by tip of the pencil.
2. Press
or
3. Press
: Set the time.
Remote Control Reset
Push
by tip of the pencil.
1. Remove the battery.
2. Press
.
3. Insert the battery.
3
AIR FLOW DIRECTION
1
Press
the desired vertical direction.
2
Press
automatically and press again to stop.
For horizontal direction, adjust
3
manually.
Note:
• Do not move the louver manually by others.
• The louver may automation positioning by some operation mode.
1113950107_EN.indd 2
1113950107_EN.indd 2
1
OPERATION (Green)
2
TIMER / CLEANING (Yellow)
3
RESET button
: adjust the time.
: Move the louver in
: Swing the air
4
REMOTE CONTROL
1
Infrared signal emitter
2
Start/Stop button
3
Mode select button (MODE)
4
Temperature button (TEMP)
5
Fan speed button (FAN)
6
Swing louver button (SWING)
7
Set louver button (FIX)
8
On timer button (ON)
9
Off timer button (OFF)
-
Setup button (SET)
=
Clear button (CLR)
q
Memory and Preset button (PRESET)
w
One-Touch button (ONE-TOUCH)
e
High power button (Hi-POWER)
r
Power selection button (POWER-SEL)
t
Quiet button (QUIET)
y
Comfort sleep button (COMFORT SLEEP)
u
Filter reset button (FILTER)
i
Set clock button (CLOCK)
o
Check button (CHECK)
p
Reset button (RESET)
5
ONE-TOUCH
Press the "ONE-TOUCH" button for fully automated operation that is
customised to the typical consumer preferences in your region of the world.
The customised settings control temperature air fl ow strength, air fl ow
direction and other settings to provide you alternate contact with "ONE-
TOUCH" of the button. If you prefer other settings you can select from the
many other operating functions of your Toshiba unit.
Press
: Start the operation.
6
AUTOMATIC OPERATION
To automatically select cooling, or fan only operation
1. Press
: Select A.
2. Press
: Set the desired temperature.
3. Press
: Select AUTO, LOW , LOW+
or HIGH
.
7
COOLING / FAN ONLY OPERATION
1. Press
: Select Cool
, or Fan only
2. Press
: Set the desired temperature.
Cooling: Min. 17
o
C, Fan Only: No temperature indication
3. Press
: Select AUTO, LOW , LOW+
or HIGH
.
8
DRY OPERATION
For dehumidifi cation, a moderate cooling performance is controlled
automatically.
1. Press
: Select Dry
.
2. Press
: Set the desired temperature.
9
Hi-POWER OPERATION
To automatically control room temperature and airfl ow for faster cooling
operation (except in DRY and FAN ONLY mode)
Press
: Start and stop the operation.
10
POWER-SELECTION OPERATION
This function is used when its circuit breaker is shared with other electrical
appliances. It limits the maximum current/power consumption to 100%, 75%
or 50%. The lower the percentage, the higher the saving and also the longer
the compressor lifetime.
Press
: Select
(for 100%),
• When the level is selected, PWR-SEL level fl ashes on LCD display for 3
seconds. In case of 75% and 50% level, number "75" or "50" also fl ashes
for 2 seconds.
• Due to the reason that POWER SELECT FUNCTION limits the maximum
current, inadequate cooling capacity may occur.
1
q
4
2
6
3
5
7
t
w
e
r
=
8
9
y
-
o
p
i
u
, MED
, MED+
,
.
, MED
, MED+
,
(for 75%),
(for 50%)
6/18/12 6:34 PM
6/18/12 6:34 PM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10n3kcv series

Table of Contents