Diagnostic
Function
RLS Siren Models 3997 & 3999 features a "walk-around" diagnostic test function. The user may invoke this
function by holding the "Air Horn" switch while turning on the vehicle's ignition switch. When the "Air Horn"
switch is released the siren will begin a timing sequence which will turn on each control output for about two
seconds. Each output, including the Arrow Stik (in Flash mode) and the siren tones will be cycled during this
sequence. The siren tones will not be heard if the Park-Kill feature is being used and the vehicle is in Park.
This timed feature enables the user to start the diagnostic function, exit the vehicle and observe a brief test can
be interrupted by cycling the vehicle's ignition switch off. After the test, the vehicle's ignition power must be
cycled off and back on to insure that everything is restored to the normal standby mode.
O p t i o n s
Lighting Switch Connector- Connectors which when soldered to the #8 wire and the user supplied power
wire offers quick disconnect service.
Microphone Extension Cable- A twenty (20) ft. microphone extension cable. Allows the siren amplifier to be
mounted up to twenty feet from the driver's area.
TM
NIGHTPROBE
Spotlight Control Module - Allows use of the RLS 3999 Siren Control to provide full control
TM
of the NIGHTPROBE
spotlight with linear acceleration from stop to full speed.
Auxiliary Relay Module - Provides eight (8) additional switched +12VDC outputs at up to 10A each, limited to
a maximum total combined current of 60A.
Specifications
Siren Section
Input Voltage -
(Note: Operation of 12V units above 15 VDC for an extended period of time may result in speaker damage.)
(Note: Operation of 24V units above 30 VDC for an extended period of time may result in speaker damage.)
Operating Current 100W:
200W:
Note: There is no 58 Watt speaker connection available.
Standby Current:
Cycle Rate:
Voltage Output ( approx. )
Audio Section
Audio Response:
Audio Distortion:
10 to 16 VDC, negative ground (earth) - 12V units
20 to 30 VDC, negative ground (earth) - 24V units
8 Amps @ 13.6V with 11-ohm load ( 100 W Spkr ) - 12Vunits
4. 5 Amps @ 27.6V with 11-ohm load ( 100 W Spkr ) - 24Vunits
14 Amps @ 13.6V with 5.5-ohm load ( 2- 100 W Spkr ) - 12V units
9 Amps @ 27.6V with 5.5-ohm load ( 2- 100 W Spkr ) - 24V units
25 mA excluding backlighting
WAIL - 11 cycles/minute.
YELP - 200 cycles/minute.
64 V peak-to-peak
3 dB down points - 500 to 3000 hz.
1000 hz. 0 dB Reference
10% or less below clipping.
1 9
Need help?
Do you have a question about the RLS 3997 and is the answer not in the manual?
Questions and answers