Installation Instructions ControlLogix AC (74-265V) Output Module (Catalog Number 1756-OA8) See page: Prevent Electrostatic Discharge See Removal and Insertion Under Power (RIUP) Understand Compliance to European Union Directive Note the Power Requirements Identify the Module Components Install the Module Key the Removable Terminal Block/Interface Module Wire the Removable Terminal Block Assemble the Removable Terminal Block and the Housing Install the Removable Terminal Block onto the Module...
ControlLogix AC (74-265V) Output Module Wire the Removable Terminal Block :LUH WKH 57% EHIRUH LQVWDOOLQJ LW RQWR WKH PRGXOH 8VH D LQFK PP PD[LPXP IODWEODGHG VFUHZGULYHU ,03257$17 3XOO WKH KRXVLQJ RII RI WKH 57% EHIRUH ZLULQJ For the Spring Clamp RTB 6WULS LQFK PP PD[LPXP OHQJWK WR ZLUH \RXU 57% ,QVHUW WKH VFUHZGULYHU LQWR WKH LQQHU KROH RI WKH 57% ,QVHUW WKH ZLUH LQWR WKH RSHQ WHUPLQDO DQG UHPRYH WKH VFUHZGULYHU...
Page 8
ControlLogix AC (74-265V) Output Module Wiring example 1756-OA8 L1-0 OUT-0 L1-0 OUT-1 Group 0 Group 0 L1-0 OUT-2 L1-0 OUT-3 L1-0 Not used L1-1 OUT-4 L1-1 OUT-5 L1-1 OUT-6 Group 1 Group 1 L1-1 OUT-7 L1-1 Not used Daisy chain to other RTBs 40178-M NOTES: All terminals with the same name are connected together on the module.
ControlLogix AC (74-265V) Output Module Assemble the Removable Terminal Block and the Housing $OLJQ WKH JURRYHV DW WKH ERWWRP RI HDFK VLGH RI WKH KRXVLQJ ZLWK WKH VLGH HGJHV RI WKH 57% 6OLGH WKH 57% LQWR WKH KRXVLQJ XQWLO LW VQDSV LQWR SODFH Groove Side edge of the RTB Groove...
ControlLogix AC (74-265V) Output Module 1756-OA8 Specifications Number of Outputs 8 (4 points/common) Module Location 1756 ControlLogix Chassis Backplane Current 200mA @ 5.1V dc & 2mA @ 24V dc Maximum Power Dissipation 5.1W @ 60 Thermal Dissipation 17.39 BTU/hr Output Voltage Range 74-265V ac, 47-63Hz Output Current Rating Per Point...
ControlLogix AC (74-265V) Output Module User Manual Publication 1756-6.5.8 Agency Certification (when product or packaging is marked) Class I Div 2 Hazardous Class I Div 2 Hazardous marked for all applicable directives marked for all applicable acts N223 The commutating dv/dt of the output voltage (OUTPUT to L2) should not exceed 0.2V/µs for loads under 50mA. The commutating dv/dt rating of the module for loads 50-500mA (OUTPUT TO L2) is 4V/µs maximum.
Page 15
ControlLogix AC (74-265V) Output Module Temperature code rating: CL I, DIV 2 GP A,B,C,D TEMP Look for temperature code rating here. The following warnings apply to products having CSA certification for use in hazardous locations. Explosion hazard! ATTENTION • Substitution of components may impair suitability for Class I, Division 2. •...
Page 16
8qrÃqrÃrp h rÃ) CL I, DIV 2 GP A,B,C,D TEMP Le code de température est indiqué ici. Les avertissements suivants s’appliquent aux produits ayant la certification CSA pour une utilisation en environnements dangereux. Risque d’explosion ATTENTION • La substitution de composants peut rendre cet équipement inadapté à une utilisation en environnements de Classe 1, Division 2.