Battery Installation; Battery Requirement - Suzuki DF25 Owner's Manual

V-twin
Hide thumbs Also See for DF25:
Table of Contents

Advertisement

Available languages

Available languages

BATTERY INSTALLATION

BATTERY REQUIREMENT

Choose a 12 Volt cranking-type lead acid bat-
tery that meets the specifications shown below.
450 Marine Cranking Amps (MCA)/ABYC,
or 330 Cold Cranking Amps (CCA)/SAE
or 70 Reserve Capacity (RC) Minutes/SAE
NOTE:
• The specifications listed above are the mini-
mum battery rating requirements for starting
the engine.
• Additional electrical loads from the boat will
require larger capacity batteries. Consult
your Suzuki dealer to determine the proper
battery sizing for your boat and engine com-
bination.
• Dual-purpose (Cranking/Deep-cycle) batter-
ies can be used if they meet the minimum
specifications listed above (MCA, CCA, or
RC).
• Do not use a Deep Cycle battery for the main
cranking battery.
• The use of Maintenance-Free, sealed, or Gel-
Cell batteries is not recommended because
they may not be compatible with Suzuki's
charging system.
• When connecting batteries in parallel, they
must be of the same type, capacity, manufac-
turer, and of similar age. When replacement
is necessary, they should be replaced as a
set. Consult your Suzuki dealer for proper
battery installation information.
BATTERY INSTALLATION
Secure the battery in a dry area of the boat,
away from vibration.
NOTE:
• It is recommended that the battery be
installed in an enclosed battery case.
• When connecting batteries, hexagon-nuts
must be used to secure battery leads to bat-
tery posts.
To hook up the battery, first connect the red
lead from the motor to the positive battery ter-
minal, then connect the black lead to the nega-
tive battery terminal.
Hexagon-
nut
Red lead
Hexagon-nut
Hexagon-
nut
Black
lead
15

Hide quick links:

Advertisement

Table of Contents
loading