Siemens COMBIMASTER CM12 Operating Instructions Manual page 9

Table of Contents

Advertisement

Earth
connection
Figure 3 Electrical Connection (CS A)
Check that the supply voltage is correct for the
inverter used by referring to the rating label.
Cable Glands (Case Size A)
8
I
V
Jumpers for
Analogue input type
Default = V
Mains
connection
OPm2 connector
LED
(SK200)
(green)
(yellow)
PG16
Note: Jumper in 'V' position = voltage input (default)
Jumper in 'I' position = current input
JP 305
connects
PI- to 0V
JP 300
JP 301
LED
Control cable connector
(PL700)
IMPORTANT
Ensure that the following tightening torques are used:
Access cover retaining screws
Gland hole covers:
Mains connector screws
PL700 Screws
Earth Connection
© Siemens plc1999 |
JP 304
connects
AIN- to 0V
I
JP 302
JP 303
V
Jumpers for
PI input type
Default = V
Control Potentiometer
(R314)
4.0Nm
1.0Nm
1.0Nm
0.5Nm
1.5Nm
G85139-H1731-U400-D2

Advertisement

Table of Contents
loading

Table of Contents