6 ALARMS AND TROUBLESHOOTING

6.1 ALARMS

Alarm List
Alarm Condition
Over-Temperature
Alarm
Optical Tx Alarm
Optical Rx Alarm
DL Input Power
Overload Alarm
ENU STATUS : 1-0-0
USER MANUAL FOR COMFLEX-6900
Table 12: MU Alarm List
Alarm when equipment temperature is higher than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold : 80℃ by default.
Alarm when Optical Transmiting power is lower than the threshold,
otherwise normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: -7dBm by default.
Alarm when Optical received power is lower than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: -10dBm by default.
Alarm when DL input power is higher than the threshold, otherwise normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: 32dBm by default.