1. Unpack the MetroLinq
Package Contents
MetroLinq™
Tools/Items Required
Flat-head screwdriver
Ethernet cables
2. Mount the MetroLinq on a Pole
1
1
Slide the pole-mount bracket onto the rails on the back of
the AP until it snaps into its secured position.
2
Use the included M3 screw to secure the bracket to the AP.
3
3
3
Feed the two steel-band clamps through the pole-mount
bracket mounting points.
4
Fasten the steel-band clamps around the pole to secure the
AP to the pole.
ignitenet.com
60 LW (ML-60-LW)
2
4
4
– 1 –
3. Grounding
2
1
1
Ensure the structure on which the unit is to be mounted is
properly grounded and in compliance with ETSI ETS 300 253.
2
Verify that there is a good electrical connection to a
grounding point (no paint or isolating surface treatment).
Use the included (M4) screw to attach a grounding wire (not
included) to the grounding point on the unit, and then to
ground.
Caution:
The earth connection must not be removed
unless all supply connections have been disconnected.
4. Connect Cables
1
1
Connect outdoor-rated Category 5e or better cable to the
RJ45 port. (The other end of this cable connects to the PoE
power injector.)
2
Install a 1G SFP transceiver in the SFP port, and then connect
fiber optic cabling to the transceiver.
The following transceivers are supported:
1000BASE-SX
1000BASE-LX
5. Connect Power
a. Using the PoE Power Injector
3
2
1
Connect outdoor-rated Category 5e or better cable from the
MetroLinq to the POE port on the power injector.
2
1
E012018-CS-R01

Advertisement

loading

Summary of Contents for IgniteNet MetroLinq 60 LW

  • Page 1 Fasten the steel-band clamps around the pole to secure the AP to the pole. Connect outdoor-rated Category 5e or better cable from the MetroLinq to the POE port on the power injector. ignitenet.com – 1 – E012018-CS-R01...
  • Page 2 Connect the 24 VDC power feed wire to the DC block “+” pin. Connect the ground/return wire to the DC block “-” pin. Manage the MetroLinq with the IgniteNet Cloud Controller Go to cloud.ignitenet.com to register your AP. Log in and select Devices from the menu. Click Add Device and 6.
  • Page 3 This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this Hereby, IgniteNet Inc. declares that the radio equipment type: device may not cause interference, and (2) this device must accept any MetroLinq™...
  • Page 4: Hardware Specifications

    1, Creation 3rd Rd., Hsinchu Science Park, inch) Hsinchu 30077, Weight 650 g (1.43 lb) Taiwan, R.O.C IgniteNet Temperature Operating: -30 °C to 55 °C (-22 °F to 131 °F) US Contact 20 Mason, Storage: -40 °C to 70 °C (-40 °F to 158 °F)

This manual is also suitable for:

Ml-60-lw