This gives you the ability to edit point-by-point, to draw
straight lines between pairs of points, or to insert other
waveforms between pairs of points:
Press the line draw... soft key
The display initially offers a line covering the entire range
of points from 0 to 99:
LINE (addrs, value)
frm (0000000,0000)
to
(0000099,0000)
exit
For the first segment, the addresses are from 0 to 9 and
the corresponding voltages go from zero to 1 V.
To provide some headroom, we'll decide to use a full-scale
range of -2 V to +2 V, so 1 volt is represented by a value
of +1024 (full-scale being +2047).
Set the screen as shown here, using the soft keys to
select the to row and the numeric keypad to enter the
value pair (9,1024).
draw line
LINE (addrs, value)
frm (0000000,0000)
to
(0000009,1024)
exit
Don't forget to press ENTER after each numeric entry.
Pressing the draw line soft key will complete segment
1 of MYWAVE.
The same screen will reappear, so that the values for
segment 2 can be entered. (It's best to set the to
address before the frm address.)
LINE (addrs, value)
frm (0000010,1024)
to
(0000019,1024)
exit
After you have done that, press the draw line soft key
again.
Continue doing this until you have entered segment 5
(there is no need to enter segment 6 because all the
values are zero). The segment 5 screen looks like this: