DS4800 OM QUICK GUIDE

READING PERFORMANCE

Version
F = 30 Near
21 cm (8.3 in) - 43 cm (16.9 in) on 0.50 mm (20 mils) codes
F = 40 Medium
25 cm (9.8 in) - 64 cm (25.2 in) on 0.50 mm (20 mils) codes
F = 60 Far
39 cm (15.4 in) - 95 cm (37.4 in) on 0.50 mm (20 mils) codes

TECHNICAL FEATURES

ELECTRICAL FEATURES
Power Supply
Max. Consumption
Main Serial Interfaces
Baud Rate
Auxiliary Interface
Baud Rate
ID-NET™ Interface
Baud Rate
Inputs
Input 1 (External Trigger), Input 2
Voltage
Current Consumption
Minimum Pulse Duration
Outputs
Output 1, Output 2
V
CE
Collector Current
V
CE Saturation
Power Dissipation
OPTICAL FEATURES
Light Source
Wavelength
Safety Class
READING FEATURES
Scan Rate (software programmable)
Aperture Angle
Oscillating Amplitude
Oscillating Frequency
Maximum Reading Distance
Maximum Resolution
ENVIRONMENTAL FEATURES
Operating Temperature
Storage Temperature
Humidity max.
Vibration Resistance
EN 60068-2-6
Shock Resistance
EN 60068-2-27
Protection Class – EN 60529
Ambient Light Rejection
PHYSICAL FEATURES
Dimensions
Weight
USER INTERFACE
LED Indicators
Multi-function Key
Display
 If the reader is used in high temperature environments (over 40 °C), use of the Beam Shutter is advised (see the Genius™
configuration program) and/or a thermally conductive support (such as the metal bracket provided).
20
Reading Distance
10 to 30 Vdc
0.75 to 0.25 A; 7.5 W
Programmable:
RS232, RS485 FD and HD
1200 to 115200
RS232
1200 to 115200
RS485 Half Duplex
Up to 1Mbaud
Optocoupled, polarity insensitive
10 to 30 Vdc
12 mA max.
5 ms
Optocoupled
30 Vdc max.
40 mA continuous max.; 130 mA pulsed max.
1V max. at 10 mA
80 mW max. at 45 °C (ambient temperature)
Semiconductor laser diode
In the range 630 to 680 nm
Class 2 – EN 60825-1; CDRH
600 to 900 scans/sec
50°
40° (-5° to 35°)
0.2 to 20 Hz; 5 Hz max @ 40°; 20 Hz max @ 10°
See reading diagrams
0° to +50 °C (+32° to +122 °F) 
-20° to +70 °C (-4° to +158 °F)
90% non condensing
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
2 g @ 70 to 200 Hz; 2 hours on each axis
30 g; 11 ms;
3 shocks on each axis
IP65
30,000 LUX
123 x 117 x 48 mm (4.8 x 4.6 x 1.9 in)
780 g (27.9 oz)
Ready, Good, Trigger, Com, Status, Power On
X-PRESS™ button
menu and diagnostic messages configurable in various languages
Max Code Resolution
mm (mils)
0.20 (8)
0.30 (12)
0.38 (15)
2 lines x 16 characters
Speed
scans/s
800
800
800