Maintenance; Troubleshooting; Recommended Action - Glendinning CRMA 16 Installation & Operation Manual

Power cord retrieval & storage system
Table of Contents

Advertisement

4.0 O
I
PERATING
NSTRUCTIONS
To operate your Cordreel:
PULL OUT only the amount of shore power cord required to reach the outside power source.
CONNECT your shore power cord to outside power source receptacle.
TURN ON outside power supply.
When ready to get underway:
TURN OFF outside power supply.
DISCONNECT cord from the outside power supply.
PUSH AND HOLD the Cordreel power switch (black rocker
switch). Cordreel will electrically retrieve the power cord and
store.
When cord is fully retracted, RELEASE the power switch to
stop the unit. NOTE: Not releasing the switch may cause the
plug to get jammed in the unit and make the next use difficult.
5.0 M
AINTENANCE
TO RELIEVE ANY KINKING that may happen Routinely extend the power cable completely, stretch it on any flat sur-
face, and allow the Cordreel to retract the cable into the reel.
INSPECT ALL AC AND DC WIRING CONNECTIONS and make sure they are free of corrosion and connections are
tight.
INSPECT THE EXTERIOR JACKET of the power cable for nicks or cuts.
IF YOUR POWER CABLE IS DIRTY, any cleaner should be compatible with the outer jacket material of the power
cable.
IF NEEDING TO REPLACE POWER CORDSET, USE ONLY 105⁰c (CRMA-30/32) of 90⁰C (CRM-16) MINIMUM RATED
CORDSETS and ensure that the outside diameter of the new cordset does not exceed that of the factory supplied
cordset.
6.0 T
ROUBLESHOOTING
ISSUE
Non-functional (either no power
or unit has power and does not
respond)
Cordreel stops retracting
while button is being pushed
PROBABLE CAUSE
Tripped breaker
Blown fuse at power source
Power wire incorrectly connected
to power source
Defective motor
Cord jammed during retraction
causing breaker to trip
!
CAUTION:
Always disconnect AND fully retract
your cable BEFORE getting underway!
Continuing to push power button
after cable is retracted may cause
damage to the motor and will cause
breaker switch to trip - reset before
next use.

RECOMMENDED ACTION

Reset breaker
Replace fuse
Check power source fuse and connections,
reconnect or replace if necessary
With power switch on and voltage across motor
wires
Reset breaker
Pay out cable and rewind
7

Advertisement

Table of Contents
loading

Related Products for Glendinning CRMA 16

This manual is also suitable for:

Crma 32Crma 30

Table of Contents