Frame rate (@ max. image resolution)
TiX1000 ...................................... 30 Hz
TiX660, TiX640, TiX620 ............. 60 Hz
Field of view (FOV) standard 30 mm lens
TiX1000 ...................................... 32.4° x 24.7°
TiX660, TiX640, TiX620 ............. 30.9° x 23.1°
Thermal sensitivity [NETD]
TiX1000 ...................................... ≤0.05 °C at 30 °C target
TiX660, TiX640 .......................... ≤0.03 °C at 30 °C target
TiX620 ........................................ ≤0.04 °C at 30 °C target
Digital zoom .................................... up to 32x
A/D conversion ............................... 16-bit
Power supply
External ...................................... 12 V dc to 24 V dc
Battery ........................................ Standard lithium-ion video
Operating temperature
with external power .................... -25 °C to +55 °C
with battery power ...................... -25 °C to +40 °C
Shop for Fluke products online at:
Storage temperature ....................... -40 °C to +70 °C
Operating altitude ............................ <2000 m
Humidity .......................................... relative humidity 10 % to
Shock .............................................. Operational: 25G, IEC 68-2-29
Vibration .......................................... Operational: 25G, IEC 68-2-6
Protection class ............................... IP54
temperature (50 mK)
Safety .............................................. meets IEC 60825-1: class 2
Electromagnetic Compatibility (EMC)
temperature (30 mK)
temperature (40 mK)
Dimensions with standard 30 mm lens
camera battery
(-13 °F to +131 °F)
(-13 °F to +104 °F)
MyFlukeStore
www.
Before You Start
Technical Description
(-40 °F to +158 °F)
95 %, non-condensing
International ................................ IEC 61326-1: Portable
Korea. ......................................... Class A Equipment (Industrial
Broadcasting &
Communication Equipment)
Class A: Equipment meets requirements for industrial
electromagnetic wave equipment and the seller or user
should take notice of it. This equipment is intended for use
in business environments and not to be used in homes.
TiX1000, TiX660 ......................... 210 mm x 125 mm x 155 mm
(8.25 in x 4.9 in x 6.1 in)
TiX640, TiX620 ........................... 206 mm x 125 mm x 139 mm
(8.1 in x 4.9 in x 5.5 in)