MARINE
COOLING SYSTEMS
Marine
electric
plants use heat exchanger
and
direct
type cooling
systems.
The only outward
difference
between
the two systems
(new design
- see illustration)
is in the type of cap used on the water-
cooled
exhaust. manifold.
The heat exchanger
system
utilizes
a pressure
cap (with filler
neck and over-
* flow
tube) while the direct
type uses a solid,
non-pressure
type cap.
To further
identify
the systems,
the tubes of the heat exchanger
can be seen or felt when the cap is removed
from
the manifold.
TO
drain systems,
turn p?tcock
located
on lower
right front side of crankcase
or if this is not provided,
loosen
cover
plate.
PRESSURE
CAP WITH HEAT
EXCHANGER SYSTEM
PRESSURE
f
SOLID CAP WITH DIRECT
rADAQTER
SYSTEM
fWASHER
ncn1
LA
BUNDLE
Uc*T VCHANGER
/
\
COOLED -.N
MANIFOLD
w
I
COOLING
L
nlIT1 Ft
I
TUBE
770'
WITH
EXCHANGER SYSTEM 1
138" WITH DIRECT SYSTEM
I
.
FIGURE 6-5 --
WATER
COOLED MANIFOLD FOR MARINE COOLING SYSTEMS
Heat Exchanger
Systein:
The heat exchanger
system
is comprised
of two circuits--a
closed
engine
clrcult
and the raw or sea water
circuit.
In the closed
circuit,
coolant
is circulated
by the engine
water
pump through the water jacket,
manifold
and returned
to the pump for recirculation.
Since this is a
closed
circuit,
antifreeze
can be added if required-
the circuit
holds 5 to S- l/2 quarts
of liquid.
In the
raw water
circuit,
the belt driven
sea water pump picks up sea water and circulates
rt through the tube
bundle where
it absorbs
and carries
away heat of the closed
circuit
which is being circulated
around the
tubes.
The heated water is sprayed
into and mixed
with the exhaust which is in turn ejected
through the
wet type silencer
and finally
is expelled
through the exhaust outlet.
Direct
Type System:
On the direct
system,
the sea water pump introduces
sea water
directly
into the
manrfold
where
It 1s circulated
throughout
the engine by the engine water pump.
The heated water
is
forced
away and injected
into the exhaust in the same way as in the heat exchanger
system.
Since the
direct
system
is of the non-pressure
type,
the solid
cap must be used..
This system
cannot be protected
with antifreeze
since it is an open circuit.
A 138' therm-
is required
with the direct
system.
63