Rs-232C Command Table - Sharp PN-455 Operation Manual

Sharp pn-455 lcd monitor operation manual
Table of Contents

Advertisement

RS-232C command table

<How to read the command table>
Command:
Direction:
Parameter:
Reply:
* A circle indicates commands which can be used in power standby mode.
Power control/Input selection, etc.
Control item
Power Setting
Input Selection
Command field (See page 40.)
W
When the "Parameter" is set in the parameter field (see page 40), the
command functions as described under "Control/Response Contents".
R
The returned value indicated under "Reply" can be obtained by setting
"????", "___?" or "???+" (repeater control) in the parameter field (see page
40).
Parameter field (See page 40.)
Response (Returned value)
Command Direction Parameter
0
W
1
POWR
R
0
1
W
2
3
INPS
4
R
Reply
Control/Response contents
Switches to standby.
Returns from standby.
0
Standby mode
1
Normal mode
2
Waiting mode
Toggle change
INPUT1 : DVI
INPUT2 : RGB
INPUT3 : Component
INPUT4 : S-Video/Video
1
INPUT1 : DVI
2
INPUT2 : RGB
3
INPUT3 : Component
4
INPUT4 : S-Video/Video
*can be used in standby mode
*
Yes
Yes
47