MAINTENANCE

WARNING:
Before inspecting, cleaning, or performing any
maintenance, make sure the switch is in the off
( O ) position, wait for all moving parts to stop, and
disconnect from the power supply. Failure to follow
these instructions can result in death, serious
personal injury, or property damage.
WARNING:
Always wear eye protection with side shields
marked to comply with ANSI Z87.1. Failure to do
so could result in objects being thrown into your
eyes, resulting in possible serious injury.
WARNING:
When servicing use only identical replacement
parts. Use of any other parts could create a hazard
or cause product damage.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline,
petroleum-based products, penetrating oils, etc.,
come in contact with plastic parts. Chemicals can
damage, weaken or destroy plastic which could
result in serious personal injury.
Find Quality Products Online at:
Electric tools used on fiberglass material, wallboard, spack-
ling compounds, or plaster are subject to accelerated wear
and possible premature failure because the fiberglass chips
and grindings are highly abrasive to bearings, brushes, com-
mutators, etc. Consequently, we do not recommended using
this tool for extended work on these types of materials. How-
ever, if you do work with any of these materials, it is extremely
important to clean the tool using compressed air.
LUBRICATION
All of the bearings in this tool are lubricated with a sufficient
amount of high grade lubricant for the life of the unit under
normal operating conditions. Therefore, no further lubrica-
tion is required.
POWER SUPPLY CORD REPLACEMENT
If replacement of the power supply cord is necessary, this
must be done by an authorized service center in order to
avoid a safety hazard.
BRUSH REPLACEMENT
See Figure 15, page 16.
 Unplug the router.
 Remove cutter bit if there is one installed.
 With a flat head screwdriver, remove the brush cap and
 Remove the brush assembly.
 Check for wear. If worn, always replace in pairs. Do not
 Replace the brush assembly.
 Make sure the notches in the washer on the spring line
 Replace the washer and brush cap and tighten with a
 Repeat for other side.
 The router is now ready for use.
11 - English
GlobalTestSupply
www.
washer.
replace one side without replacing the other.
up so that the washer on the spring lies flat.
screwdriver. Do not overtighten.
.com