Download Print this page

Advertisement

Quick Links

P-LED.com
(325) 227.4577
INSTALLATION GUIDE

Advertisement

loading

Summary of Contents for Principal LED Street Wrap Gen 2

  • Page 1 P-LED.com (325) 227.4577 INSTALLATION GUIDE...
  • Page 2: Getting Started

    Note: If job measurements do not correspond to provided drawing, call • Portable Rechargable Drill • Wire Strippers Aluminum Principal LED immediately at (325) 227-4577. Remember: No more than • Wire Snips -5/16" hexbit and unibit Street Wrap 1.25”W x 96”L x 2.1875”H four (4) 96”...
  • Page 3 STREET WRAP GEN 2™ MOUNTING BRACKET LAYOUT 1. Use a chalk line, gauge, laser level, or other means to be certain the run is straight, marking locations for brackets. Install three (3), evenly spaced, mounting brackets per section. Ensure there are at least two inches between the end of the track and the mounting bracket as shown in the picture above.
  • Page 4 Base Mount INSTALLING STREET WRAP GEN 2™ INTO MOUNTING BRACKETS Connect wires from one section to another using red butt splice wire connectors, silicone filled wire nuts or TE connectors. No more than two (2) 96” units in a series.
  • Page 5 HOW TO WIRE RGB STREET WRAP GEN 2™ POWER AMPLIFIER FIGURE Also see RGB Controller spec sheet for more information on wiring.
  • Page 6: Very Important

    Reinstall light tape to desired length ensuring to silicone down the tape and using silicone to seal cuts made to light tape. NOTE: Always test-light the Street Wrap Gen 2™ after making field cuts. Never connect AC voltage lines to LEDs on the Street Wrap Gen 2™.
  • Page 7 CORNER MOUNTING OPTIONS OPTION 2 OPTION 1 INSIDE BUTT JOINT INSIDE MITER CUT CORNER OUTSIDE BUTT JOINT CORNER OUTSIDE MITER CUT CORNERS OUTSIDE BUTT JOINT INSIDE BUTT JOINT CORNER...
  • Page 8 MOUNTING STREET WRAP GEN 2™ ON INCLINE OR VERTICALLY When mounting Street Wrap Gen 2™ on an incline or vertically, two things must be prevented. First the Street Wrap Gen 2™ must be kept from sliding down, while still allowing for expansion/contraction with temperature changes.
  • Page 9 Low Voltage (OUT) 96” 96” VERY IMPORTANT: KEEP LOW VOLTAGE CIRCUITS ELECTRICALLY SEPARATE, DO NOT CONNECT TRANSFORMERS OR LEDs FROM DIFFERENT 96” STREET WRAP GEN 2™ TOGETHER OR CONNECT MORE THAN FOUR 96” STREET WRAP GEN 2™ TO A 96W POWER SUPPLY!
  • Page 10 P-LED.com (325) 227-4577 3490 Venture Drive, San Angelo, Texas 76905 info@p-led.com REV20181220...