Troubleshooting The Unit; Troubleshooting - Sharp AL-2030 Operation Manual

Digital multifunctional system
Hide thumbs Also See for AL-2030:
Table of Contents

Advertisement

8

TROUBLESHOOTING THE UNIT

This chapter describes misfeed removal and troubleshooting.
For problems with the printer function or the scanner function, see the online manual
or the Help file for the printer/scanner driver.

TROUBLESHOOTING

If any problem occurs, check the list below before contacting our Technical
Assistance Department.
Problem
Unit does not
operate.
Blank copies
Copies are too
dark or too light.
Dust, dirt,
smudges appear
on copies.
Striped copies
Paper misfeeds
frequently.
Images rub off the
copy easily.
Printing is not
uniform between the
edges of the paper
and the center.
Possible cause
Unit plugged in?
Power switch on?
Side cover closed securely? Gently close the side cover.
Front cover closed?
Is the original placed face
down on the document
glass or face up in the SPF?
Is the scan head locking
switch locked?
Is original image too dark or
too light?
Is the unit in the automatic
exposure mode?
Is the unit in the photo
exposure mode?
Document glass or SPF dirty? Clean regularly.
Original smudged or blotchy? Use a clean original.
Is transfer charger clean?
Non-standard paper used? Use standard paper. If using special
Paper curled or damp?
Pieces of paper inside unit? Remove all pieces of misfed paper.
Paper guides in the paper
tray not set properly?
Too much paper in the paper
tray or multi-bypass tray?
Is the paper too heavy?
The fusing temperature is
not appropriate.
Paper damp?
The fusing temperature is
not appropriate.
Solution
Plug the unit into a grounded outlet.
Turn the power switch on.
Gently close the front cover and then
close the side cover.
Place the original face down on the
document glass or face up in the
SPF.
Unlock the scan head locking switch.
Adjust the exposure manually.
Adjust the automatic exposure level.
Cancel the photo exposure mode.
Clean the transfer charger.
papers, feed the paper through the
multi-bypass tray.
Store paper flat in the wrapper in a
dry location.
Set the guides properly depending on
the paper size.
Remove excessive paper from the
tray.
Use paper within the specified range.
In the user programs, set "Fusing
temperature setting when the bypass
tray is used" (program 29) to "2 (High)".
Replace with dry paper. If the unit is
not used for long time, remove the
paper from the paper tray and store it
in its wrapper in a dry location.
In the user programs, set "Fusing
temperature setting when the bypass
tray is used" (program 29) to "1 (Low)".
Page
12
12
11
11
47, 48
9
49
50
49
59
60
14
63
15, 18
8
15, 17
14
56
72
56
61

Hide quick links: