7.2 Maintenance tasks
The motor gearbox has lifetime lubrication. Changing the gear oil is usually unnecessary.
Caution!
For the following tasks it must be ensured that the load cannot start moving by itself after it is
disconnected from the drive.
7.2.1 Checking worm gear wear and shaft play
1.
Put the motor gearbox in an unloaded position, for example with the vent closed;
2.
Switch off the power;
3.
Disconnect the motor gearbox from the drive train, so the output shaft should be able to turn freely;
4.
Check the play in the gear unit by turning the output shaft of the drive.
If there is clearly noticeable play, the drive should be dismounted and returned to the manufacturer for inspection.

8 Dismounting

Dismounting may only be carried out by qualified staff (see Section 1.3).
Risk of injury or death! Risk of injury or death due to electrical or mechanical forces!
Before starting to work on the motor gearbox or related parts, always switch the power off at the master
switch or operating switch and lock it out with a padlock to prevent switching on again.
Risk of injury or death! Risk of injury or death due to falling objects!
Cordon off the hazard area with barrier tape.
Use a work platform, or lift the motor gearbox using hoisting equipment and appropriate slings fitted
around the output shaft.
Attention!
Motor gearbox components may only be replaced or repaired by an authorised service representative of
De Gier
8.1 Dismounting the motor gearbox from the drive train
1.
Put the drive unit of the motor gearbox in an unloaded position, for example with the vent closed;
2.
Disconnect all wiring;
3.
Disconnect the output shaft from the driven system;
4.
Replace the vent plug with an M12 sealing plug;
5.
Dismount the motor gearbox unit from the system.
De Gier B.V., Westlandseweg 9, 2291 PG WATERINGEN, THE NETHERLANDS, Tel. +31 (0)174 292089, Fax +31 (0)174 295644, E-mail: sales@degier.nl
INSTALLATION MANUAL
Maintenance and dismounting
www.degier.eu
Version 1 – 2014 / 06 / 11