Installation Instructions - ABB Ability Installation Manual

Smart sensor
Hide thumbs Also See for Ability:

Advertisement

A B B A B I L I T Y ™ S M A R T S E N S O R I N S TA L L AT I O N I N S T R U C T I O N S
2
Items needed
WARNING: Direct skin exposure to solvents and/or
threadlocker could cause discomfort or injury, including but
not limited to burning or skin irritation. Use appropriate
1
protective gloves and goggles when following these
instructions.
Items included in the ABB Ability™ Smart Sensor kit:
1
Clamp-action mounting bracket
2
Hexagon socket screws (2 qty) M4 x 8 mm
3
Hexagon socket set screw (1 qty) 1/4" x 5/16" (UNF 28)
4
ABB Ability™ Smart Sensor
Additional items needed but not included in the kit:
Degreasing agent
Rubber gloves
Safety goggles
Allen wrench (3 mm or 1/8")
Loctite™ Blue Threadlocker
Loctite™ 454 or similar glue

Installation instructions

Where to mount:
1.
Sensor must be located between the drive-end and non-drive-
end bearings, as close to the center as possible. Note: The sensor
mount cannot be removed after installation.
2.
For best Bluetooth® communication, mount the sensor with a
clear line of sight to any communication devices to be used: your
smartphone or a Bluetooth® gateway.
3.
The mounting orientation must be such that the A-axis on the
sensor housing is parallel to the rotating shaft. If this is not
physically possible, the T-axis must be parallel to the rotating
shaft.
Supported motors
This mounting instruction applies for fin-cooled motors up to frame sizes equivalent to IEC 450.