Page 1
Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS1NL/SS1NH/SS1VL/SS1VH SS1NL/SS1NH SS1VL/SS1VH Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo 675-8511, Japan Tel : [81]-(0)79-422-1122 Fax: [81]-(0)79-422-0112 Copyright (C) 2015 by TLV Co., Ltd. All rights reserved.
1 MPa = 10.197 kg/cm , 1 bar = 0.1 MPa For products with special specifications or with options not included in this manual, contact TLV for instructions. The contents of this manual are subject to change without notice.
When disassembling or removing the product, wait until the internal pressure equals atmospheric pressure and the surface of the product has cooled to room temperature. Disassembling or removing the product when it is hot or under pressure may lead to discharge of fluids, causing burns, other injuries or damage.
Page 4
3. Configuration SS1NL/SS1NH Horizontal 11 10 SS1VL/SS1VH Vertical Description Description Body Cover Bolt Cover** Bimetal Air Vent Strip Float Screw Orifice Spring Washer Orifice Gasket Nameplate Screen Connector Cover Gasket Pipe/Flange * M = Maintenance Kit; R = Repair Kit; F = Float; replacement...
7. Install a check valve at the trap outlet whenever more than one trap is connected to the condensate collection pipeline. 8. The use of unions is recommended to facilitate connection and disconnection of screwed models. Allowable lnclination SS1NL/SS1NH SS1VL/SS1VH 5˚ 5˚ 5˚ 5˚ 5˚ 5˚...
(When conducting a visual inspection, flash steam is sometimes mistaken for steam leakage. For this reason, the use of a steam trap diagnostic instrument such as TLV TrapMan is highly recommended.) Flash Steam...
Page 8
(SS1VL/SS1VH only); which may fall out when the cover (Fig. A) is removed Cover Gasket 7 SS1NL/SS1VL: Replace with a new gasket if worn or Remove if damaged damaged SS1NH/SS1VH: Replace with a new gasket, do not apply...
Page 9
9. Instructions for Plug / Holder Disassembly and Reassembly The seal on the threaded plugs/holders found on TLV products is formed by a flat metal gasket. There are various installation orientations for the gaskets, such as horizontal, diagonal and downward, and the gasket may be pinched in the thread recesses during assembly.
10. Troubleshooting If the expected performance is unachievable after installation of the steam trap, read chapters 5 and 6 again and check the following points for appropriate corrective measures. Problem Cause Remedy No condensate Float is damaged or filled with Replace with new float is discharged or condensate...
Subject to the limitations set forth below, TLV Corporation, a North Carolina corporation (“TLV”) warrants that products which are sold by it or TLV International, Inc., a Japanese corporation (“TII”), which products (the “Products”) are designed and manufactured by TLV Co., Ltd., a Japanese corporation (“TLVJ”), conform to the specifications published by TLV for the...
Page 12
WARRANTY NOT NEGATED HEREBY, AND ANY IMPLIED WARRANTY NOT NEGATED HEREBY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DO NOT COVER, AND NEITHER TLV, TII NOR TLVJ WILL IN ANY EVENT BE LIABLE FOR, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO LOST PROFITS, THE COST OF DISASSEMBLY AND SHIPMENT OF THE DEFECTIVE PRODUCT, INJURY TO OTHER PROPERTY, DAMAGE TO BUYER’S OR THE...
Need help?
Do you have a question about the SS1NL and is the answer not in the manual?
Questions and answers