8. Freeze Timer (S4 dip switch 9 & 10)
Adjust to proper specification, or the icemaker may not operate correctly.
The freeze timer setting determines the maximum allowed freeze time to prevent
possible freeze-up issues. Upon termination of the freeze timer, the control board initiates
the harvest cycle or pump-out cycle. After 2 consecutive freeze timer terminations, the
control board shuts down the icemaker. In this case, see "II.I.3. Low Ice Production"
for possible solutions. The freeze timer is factory set and no adjustment is required.
Before changing this setting, contact Hoshizaki Technical Support at 1-800-233-1940 for
recommendations.

9. Pump-Out Pump Motor Direction (S5 dip switch 1)

Do not adjust. This must be left in the factory default position or the icemaker will
not operate correctly.
The pump-out pump motor direction setting determines pump motor rotation during
pump-out.
On models with a drain valve pump motor rotation doesn't change at pump-out.
Pump motor rotates in forward direction and drain valve is energized for pump-out.
On models with a check valve, pump motor rotation reverses at pump-out.
Pump motor rotates in reverse direction and opens check valve for pump-out.
S5 Dip Switch Setting
No. 1
OFF
ON
NOTICE
S4 Dip Switch Setting
No. 9
No. 10
OFF
OFF
OFF
ON
ON
OFF
ON
ON
NOTICE
Pump-Out Components
Pump Motor Forward Rotation and Drain Valve
Pump Motor Reverse Rotation and Check Valve
36
Time
(min.)
60
50
70
75