Fagor 10iE Installation & Operation Manual page 23

Table of Contents

Advertisement

TTL multiplying factor (subdivision). Independent for each axis.
PAR02
Options: x4, x2, x1 and x0.5.
The factory setting is x4 and it is the one used for FAGOR linear encoders.
When using rotary encoders on linear axes, it should be calculating according
to the number of pulses
resolution as per the formula:
Where:
External multiplying factor when using distance-coded reference marks or
PAR03
TTL signals.
Independent for each axis. It is not required when using absolute feedback.
Options: 1, 5, 10, 20, 25, 50.
Factory setting: 1
Signal
TTL
TTL dif.
In the table, X means that the bit is irrelevant.
Note:
(Soft: 01.xx) - 10iE-20iE - Installation/Operation - DRO installation - (23/35)
of the encoder, leadscrew pitch and the desired
p = Pulses per turn of the encoder
P = Leadscrew pitch in mm/turn
R = Resolution in mm/pulse
F = Multiplying factor to be applied.
PAR00
Model
XXXXXXXX
MT / MKT
CT
FT
MTD
MX / MKX
CX
SX
GX
0000000X
FX
LX
MOX
COX
SOX
GOX
FOX
LOX
P
p
=
--------- -
RxF
Feedback parameters
PAR01
PAR02 PAR03
mm
0.005
4
0.001
PAR14
X
00X0XX00
5
00X00010
25
00X01010
10
00X00110

Advertisement

Table of Contents
loading

This manual is also suitable for:

20ie10ie-b20ie-b

Table of Contents