Hotsy 1200 Series Operator's Manual page 14

Hot water, gas engine , gas oil fired
Hide thumbs Also See for 1200 Series:
Table of Contents

Advertisement

Operations
Battery
WARNING: Batteries generate explosive gases
during normal battery operation. DO NOT expose
the battery to flame or sparks as these gases may
ignite.
AVERTISSEMENT: Les batteries génèrent des gaz
explosifs au cours de leur fonctionnement normal.
NE PAS exposer la batterie aux flammes ou aux
étincelles, car ces gaz pourraient s'enflammer.
WARNING: Battery fluid is highly acidic. If battery
fluid contacts skin or clothing, wash immediately
with soap and water. If battery fluid enters eye,
immediately flood eye with running cold water for
at least 15 minutes and get immediate medical
attention.
AVERTISSEMENT: Le liquide de batterie est très
acide. Si le liquide de batterie entre en contact
avec la peau ou les vêtements, laver immédiate-
ment à l'eau et au savon.Si le liquide de la batterie
entre en contact avec les yeux, rincer immédiate-
ment les yeux avec de l'eau froide pendant au
moins 15 minutes, puis obtenir des soins médicaux
immédiats.
1. Install battery (battery not included) in battery box
as shown. Use a standard automotive battery
minimum 500 CCA (Cold Cranking Amps). It is
recommended that a dual cell battery (a battery
with a separate cell for emergency starting) be
used.
14
2. To reduce the possibility of sparking attach the
3. Install battery box lid and secure with strap
Oil Burner
Burner Air Adjustment: The oil burner on this
machine is preset for operation at altitudes near 500
feet. If operated at higher altitudes, it may be necessary
to adjust the air band for a #1 or #2 smoke spot on the
Bacharach scale.
To adjust, Loosen locking screw found on the air band.
Start machine and turn burner ON and close air band
until black smoke appears from burner exhaust vent.
Note air band position. Next, slowly open the air band
until white smoke just starts to appear and note air
band position, again. Rotate the air band halfway
between to the previously noted positions. Tighten
locking screws. Typical distance from the 'black smoke'
position is roughly 3/8"-1/2" more open from the point of
visible black smoke, but may vary based upon local
operating conditions.
Black
Cable
Adjust the burner to your operating location's environ-
ment as-needed for best smoke spot and performance
compliant with local, state, and federal regulations.
Red
Example: a unit preset at a factory at 1700 feet altitude
Cable
with an air band of 1.1" and fuel pressure of 190 PSI
with Ambient temperature of 72 °F and a relative
humidity of 84% using #2 Diesel fuel oil. The unit is
shipped to a location at 5300 feet altitude with ambient
air temperature of 59 °F and a relative humidity of 25%.
The air band required adjustment to 1.8" opening and
fuel pressure lowered to 150 PSI for a high altitude
adjustment for both heat input adjustments and
combustion air intake with the same fuel type.
Hotsy 1200 Operator's Manual 8.914-366.0 - AL
battery cables in the following order. First attach
the positive battery cable (red) to the positive "+"
terminal of the battery. Next, attach the negative
battery cable (black) to the negative "-" terminal of
the battery. To disconnect the battery, remove the
cables in the opposite order as installed.
provided.
For higher altitudes, the air band opening may
need to be increased; for lower altitude, the air
band may need to be decreased.
For higher humidity, the air band opening may
need to be increased; for lower relative
humidity, the air band may need to be
decreased.
For higher ambient temperatures the air band
opening may need to be increased; for lower
ambient temperatures, the air band opening
may need to be decreased.